User's Manual

Table Of Contents
USER MANUAL
PRODUCT DESCRIPTION
19
Power button (A):
If you press this button while the ML-N4000 is operational, the device
switches to sleep mode.
If the ML-N4000 is operational and this button is pressed together with the
trigger/wake button (B), the ML-N4000 turns off completely.
You cannot turn off the ML-N4000 using this button when the device is
connected to a PC and the Connect LED is lit.
In this case, you can turn off the ML-N4000 via the Logger menu of the
XORAYASuite. Here, you may choose between two options, i.e. Shutdown and
Shutdown (no wake up). ( Logger)
Trigger/wake button (B):
The function of this button depends on the ML-N4000 state. The following
table describes these functions as delivered. Users can configure this
behaviour via the XORAYASuite in the settings of the button interface.
( Button)
State of the ML-N4000
Function
Sleep mode
ML-N4000 wakes up
Switched on
Start HDD recording
Switched on, recording active
Short press: Setting a mark (an event) in
the recording
Long press (3 seconds at least): Stop
current recording
Service interface (C):
In case of errors, this interface is used as a debugging interface by the X2E
support team.
Default button (D):
Press the default button with a pointed object for at least 3 seconds to reset
all ML-N4000 settings to factory defaults.
Status LEDs of the log interfaces (E):
A constantly lit status LED indicates an existing and activated log interface
on the corresponding slot. The LED flashes when messages are received.