User's Manual

Table Of Contents
USER MANUAL
XORAYASUITE
83
A2L configuration:
Click Open A2L file (3) and select the description file that corresponds
with the ECU.
The XORAYASuite reads the A2L file and configures the CCP
connection accordingly.
If Overwrite alias with ECU name under Settings (6) is activated,
Alias is also changed.
If supported by the A2L file, the XORAYASuite automatically runs an
EPK version check with the ECU and displays the result via the
Traffic light for the EPK check (4).
You can also execute this check manually via the EPK button.
Levels of the Traffic light for the EPK check (4):
green check successful
yellow check not possible
red check not successful
Signal configuration:
Click Open selection file (5) and select a suitable XML, CFG or LAB file.
or
Click Signal selection and select the signals manually. ( Filter)
The XORAYASuite calculates the expected percentage of the bus load
increase.
The result evaluation is displayed via the Traffic light for the bus
load (7).
Configure the levels of the Traffic light for the bus load (7):
Right-click on the traffic light and then on Edit traffic light settings for
this interface type.
Specify the percentage limit between green and yellow (standard: 50).
Specify the percentage limit between yellow and red (standard: 80).
Click OK.