User's Manual
ISM4 INSTALLATION & PROGRAMMING MANUAL 
30
Edit Mode - Navigate Macros
Press the Front Panel Prev or Next Buttons and observe the LED’s to navigate Source ON and OFF Macros as 
follows: 
Figure 10 Front Panel Navigation – Edit Mode (Navigating Macros) 
SEQUENCE  In Normal Operating Mode, press for 2 seconds (Indicated by the first blink of the Active Source 
LED) to enter Edit Mode. This will allow navigation of Source ON and OFF Macros. The Source 1 
and Program LED’s will illuminate solid green, by default, to indicate Edit Mode, Source 1 ON 
Macro selected. Source 1 LED green and Program LED orange indicates Source 1 OFF Macro 
selected. Source 2 LED green and Program LED green indicates Source 2 ON Macro selected. 
Source 2 LED green and Program LED orange indicates Source 2 OFF Macro selected, etc. 
PREV  In Edit Mode a quick 1 second press will Navigate to the previous Command Structure. A press 
of 2 seconds (Indicated by the first blink of the Active Source LED) will navigate to the previous 
ON or OFF Macro. Wait for the Source LED of the newly selected Command Structure or Macro 
to flash once before pressing any more buttons. To exit Edit Mode and enter into Normal Mode 
press the PREV button for 5 seconds (Indicated by the second blink of the Active Source LED) or 
cycle power off and on. 
NEXT  In Edit Mode a quick 1 second press will navigate to the next Command Structure. A press of 2 
seconds (Indicated by the first blink of the Active Source LED) will navigate to the next ON or OFF 
Macro. Wait for the Source LED of the newly selected Macro to 
flash once before pressing any 
more buttons. 
TEST  In Edit Mode press to Test the selected Source ON or OFF Macro. Emitters must be connected 
to the ISM4 and appropriate Sources to test Macros. 
DELETE  In Edit Mode, a quick 1 second press will delete the current Command Structure.  A 2 second 
press (Indicated by the first blink of the Active Source LED), will delete the current Macro. A press 
of 5 seconds (Indicated by the second blink of the Active Source LED) will delete the entire Macro 
Table (all Macros). 