Digital echo-charge Owner’s Manual Xantrex Digital echo-charge Battery Charger
Thank you for purchasing a Xantrex Digital echo-charge. Xantrex Technology Inc. takes pride in manufacturing quality products specifically designed to meet your power requirements. The Digital echo-charge is designed to operate with any DC charging source to charge the starter or auxiliary battery. For your convenience, service is available world-wide by qualified service centers. If you have any questions about your Digital echocharge, please contact Xantrex toll free: 1-800-670-0707.
INTRODUCTION The Xantrex Digital echo-charge is specially developed for charging an auxiliary battery with FreedomTM or Fleet Power® Inverter/Chargers or with any charging source. The Digital echo-charge automatically switches ON and OFF, charging a starter or auxiliary battery without affecting the main house battery bank. The maximum charge current is 15 amps when the starting battery is 1/2 volt to 1 volt DC less than the house battery.
THINGS YOU SHOULD KNOW Use only deep-cycle batteries in your house battery bank. Only similar batteries should be connected together in one bank. Do not connect old and new batteries together or wet and gel cell batteries together. Always use properly sized terminals and cables for your interconnecting battery cables. Starter battery and house battery banks should not be mixed in the same bank.
BEFORE YOU BEGIN The Digital echo-charge should be unpacked immediately upon receipt, and inspected to determine if any shipping damage has occurred. No special handling is necessary; however, care should be used to avoid dropping the unit or exposing it to dust and moisture.
INSTALLATION PRECAUTIONS Caution: To reduce the risk of electric shock and prevent premature failure from corrosion, do not mount where exposed to rain, drip or spray. Caution: Risk of electrical shock. Do not remove cover. No user serviceable parts inside. Refer service to qualified service personnel at a factory authorized service center or at the factory. Caution: Always wear safety glasses for eye protection when working with batteries.
INSTALLATION WARNING Make sure all charging sources are switched OFF and no charging voltage is present before beginning installation. Prevent unnecessary damage by carefully following the installation instructions. Battery Connections Two feet of 16 gauge wire with a ring terminal on the end is connected to the Digital echo-charge unit. Connect the ring terminals to the batteries as indicated. Connect from the echo-charge: • Ground wire (black) to the negative battery ground.
INSTALLATION WARNING Never disconnect battery cables while the charger is in operation.
OPERATION When the input voltage is 13.0/25.5 volts DC or higher, echo-charge automatically switches ON. The LED glows a steady green. When the input voltage is lower than 13.0/25.5 volts, the echo-charge automatically switches OFF, and the LED blinks green. The output voltage of echocharge is limited to 14.4/28.8 volts. When it reaches 14.4/28.8 volts, the charge current will decrease, maintaining a float condition. The starter battery will be fully charged without overcharging.
OPERATION It is important to install the Digital echo-charge in a well-ventilated location. An elevated temperature may cause the Operation LED to glow red and turn the echo-charge OFF. When the temperature cools down, the LED will return to green and the Digital echo-charge will resume normal operation.
TROUBLESHOOTING PROBLEM LED is red. Thermal shutdown THINGS TO CHECK 1. Check to see that the Digital echo-charge has sufficient air flow and ventilation around it. 2. Check the battery connections. 1. Check the difference in voltage between the house battery and the starter battery. If the difference is greater than 2 volts, the Digital echo-charge will reduce the charge current.
GLOSSARY AGM (Absorbed Glass Mat) Battery A lead acid, maintenance-free battery. Ah Capacity The ability of a fully charged battery to deliver a specified quantity of electricity (Amp-Hr., Ah) at a given rate (Amp, A) over a definite period of time (Hr.).
GLOSSARY Gel Cell Battery A type of battery that uses a gelled electrolyte solution. These batteries are sealed and are virtually maintenance-free. Not all sealed batteries are the gel cell type. Ground The reference potential of a circuit. In automotive use, the result of attaching one battery cable to the body or frame which is used as a path for completing a circuit in lieu of a direct wire from a component. This method is not suitable for connecting the negative cable of the inverter to ground.
WARRANTY What does this warranty cover? This Limited Warranty is provided by Xantrex Technology, Inc. (“Xantrex”) and covers defects in workmanship and materials in your Xantrex echo-charge. This warranty lasts for a Warranty Period of 12 months from the date of purchase at point of sale to you, the original end user customer. This Limited Warranty is transferable to subsequent owners but only for the unexpired portion of the Warranty Period.
WARRANTY What does this warranty not cover? This Limited Warranty does not cover normal wear and tear of the product or costs related to the removal, installation, or troubleshooting of the customer’s electrical systems.
WARRANTY Some states and provinces do not allow limitations or exclusions on implied warranties or on the duration of an implied warranty or on the limitation or exclusion of incidental or consequential damages, so the above limitation(s) or exclusion(s) may not apply to you. This Limited Warranty gives you specific legal rights. You may have other rights which may vary from state to state or province to province.
SPECIFICATIONS MODEL echo-charge 12V echo-charge 24V Input (House Battery) Output ON 13.0 to 17.0 Volts 26.0 to 33.0 Volts Output OFF <12.9V >17.0V <25.5V >34.0V Charge Current 15.0 Amps Maximum 15.0 Amps Maximum Reverse Current 0.0005 Amps 0.0015 Amps Voltage Limiting 14.4 Volts 28.8 Volts Output PROTECTION • Input and output are reverse polarity protected. • Input is not protected against a voltage that is greater than 36 Volts DC.