Owner's Guide Inverter 300
14
Figure 6 Hardwiring the 300 Inverter to a 12 Volt Battery
To hardwire the inverter to the battery:
1. Cut the clips off the cable clip wire assembly. (The
Caution!
Fire hazard.
The wires in most 12 volt sockets or power outlets
are not large enough for loads greater than 150
watts: they will overheat and present a fire hazard.
For loads greater than 150 watts, connect the
inverter directly to the battery and use
appropriately sized wires like those in the battery
clip wire assembly provided with the inverter.
➂
②
①
④
➄
–
+
①
300 Inverter
②
3.3mm
2
(12 AWG) red wire from the
positive inverter terminal to the positive battery terminal
(via the fuse and the switch)
➂
40 amp automotive
fuse
④
12 volt, 40 amp disconnect switch
➄
12 volt
battery
3.3mm
2
(12 AWG) black wire from the negative
inverter terminal to the negative battery terminal