6. Remove the nuts from the DC terminals of the inverter.
7. Place the red ring connector on the red (positive +) DC
terminal on the inverter, and then screw the red nut on
until it is snug. Do not over tighten.
8. Fasten the positive terminal (red wire) to the positive
battery post.
9. Fasten the negative terminal (black wire) to the
negative battery post.
10. Place the black ring connector on the black (negative –)
DC terminal on the inverter, and then screw the black
nut on until it is snug. Do not over tighten.
11. Turn on the in-line switch.
12. Turn on the inverter’s On/Standby switch. The
PWR
light
comes on, and AC power is available at the outlet.
Warning!
Risk of damage to the 300 Inverter.
Reversing the positive and negative battery
cables will damage the inverter and will void
your warranty.
Before connecting the inverter to the battery,
double check the connections: the red wire must
be connected to the red terminal on the inverter
and the positive (+) terminal on the battery; the
black wire must be connected to the black
terminal on the inverter and the negative (–)
terminal on the battery.