- Xantrex International User's Manual Inverter/Charger PROsine 2.0

Specifications
A–2 445-0089-01-01
Electrical Specifications: Invert Mode
DC Input
Operating voltage range 10.0V–16.0V
Safe non-operating voltage range 0–18Vdc
Nominal current at full load 200A
AC Output
Output voltage 117Vac
Continuous power 2.0kW, 2.0kVA to 40°C max. ambient
Surge power 4.5kW for 5s
Max short-circuit current 55Arms, 55Apk
Frequency 60.0Hz ±0.05%
Wave shape Sine
THD (over load range of 0–2.0kW
resistive)
2%
Power derating above 40°C ambient temp See “Invert Power Derating vs. Ambient
Temperature” on page A–6.
Peak efficiency 87%
Full load efficiency 83%
Other
Load power factor range 0–1, inductive, capacitive, or nonlinear, to
2kVA
No load input power (producing output
voltage)
25W
Load sense power 4W (1s interval) 2W (3s interval)
Standby mode power draw
(no output, display off)
≤0.5W
Off mode current draw 2mA