Battery Status Monitor Operator's Guide TM500A

18 © 2001 Xantrex Technology Inc.
P/N 973-0012-01-02 Rev. A 05/01
Setting Parameters (continued)
CHARGED Indicator Setup (continued)
The fully-charged voltage parameters are now set. To allow the voltage
only setting to trigger the fully-charged LED, the amperage setting must be
switched OFF.
Step B Switching OFF the Amperage Detection
1B. Press the SELECT button until the Amperage LED (
A
) is illuminated.
2B. Press the SELECT and RESET buttons simulataniously until the LED
display flashes.
3B. Press the RESET button until the display indicates OFF.
4B. Press SELECT button to accept.
The TM500A is now setup to trigger the CHARGED indicator LED ( )
when the voltage level equals or exceeds the value programmed in Step A.
When this voltage parameter is met, the CHARGED indicator LED flashes
approximately every four seconds.
NOTE: The CHARGED indicator remains ON (solid) even when the
batteries are discharging, until reset.
Figure 3-5
Setting the CHARGED Indicator Voltage Level
Figure 3-6
Turn Amps OFF for VOLTAGE ONLY Detection
14.4
Set Voltage Level
2A
Voltage LED
Illuminates to Indicate
the Voltage Function
is Selected
3A
1A
4A
OFF
Set Amps to
OFF
1B
4B
2B
Amperage LED
Illuminates to Indicate
the Amperage
Function is Selected
3B
3.0 CONFIGURATION