Manual

Indicator LEDs on the Onboard Display Panel and Optional Remote Panel
975-0401-01-01 3–5
Table 3-1
Interpreting Fault and Warning Indicators
Fault or Warning
Condition
Temp Fan AC Battery Fuse Charger Remote Fault
Solution
High Battery Temp
warning (>50°C)
Check the batteries. Do not charge a battery that is
rated other than 12 V nominal for all 12 V chargers or
24 V nominal for all 24 V chargers. Check that the
battery type and temperature settings match the actual
battery and its conditions.
Disconnect the battery (or batteries) to stop charging.
Allow the battery (or batteries) to cool to normal
operating temperature. If the temperature increases
further, the battery charger will display a fault, and
shut down. The battery (or batteries) may become
damaged if overheated. See Appendix A,
“Specifications”.
Flashing LED Solid LED
F
u
s
e
C
h
g
r
R
e
m
TC2 Series BattChg Owners Guide.book Page 5 Tuesday, July 1, 2008 11:55 PM