Manual

Introduction
1–16 975-0401-01-01
Limit the maximum charger output current (20, 40, 60,
80, and 100% of charger rating) to lower the current
drawn from the generator or AC source
Set the charger to
ON or on STANDBY
Set or cancel an equalization cycle
Display faults and warnings
Display basic battery level and settings
Item Description
1
ON/STANDBY Button
Press to enable or disable the charger while AC power is
connected.
When in Setup Mode: Press to select the Charger Mode: two or
three-stage.
To set or cancel an Equalization program: Press and hold both the
Status and
ON/STANDBY buttons for more than five seconds.
2 Charging Output (%) LEDs
The LEDs illuminate a progress bar displaying the present total
output charge current as a percentage of the maximum charge
current. The numbers below the LEDs represent the percentage
values. See 2a on Figure 1-7 on page 1–15.
NOTE: The charger maximum current can be set using the Remote
Panel.
An LED may flash intermittently in combination with a solid Fault
LED to indicate a fault or with a flashing Fault LED to indicate a
warning condition. The icons on the right side of the LEDs
represent different types of faults and warnings. See 6a on Figure
1-7 on page 1–15.
TC2 Series BattChg Owners Guide.book Page 16 Tuesday, July 1, 2008 11:55 PM