Freedom SW Stacking Guide
Freedom SW Inverter/Charger Parallel Stacking Configuration
120 VAC only
Freedom SW Inverter/Charger Series Stacking Configuration
120 and 240 VAC
DOC PN: 97-0026-01-01_Rev-A
NEUTRAL
GROUND
Main
Distribution Panel
30A
L1
NEUTRAL
GROUND
CLEAR FAULT
RESET
INVERTER
ENABLED
Inverter
On
AC/
Charge
Fault
FREEDOM SW INVERTER/CHARGER
STACKINGXANBUS INTERFACE
Vented Battery
Enclosure
12Vdc or
24Vdc
xantrex
Vehicle Chassis
Ground
AC IN
CLEAR FAULT
RESET
INVERTER
ENABLED
Inverter
On
AC/
Charge
Fault
FREEDOM SW INVERTER/CHARGER
STACKINGXANBUS INTERFACE
WARNING: INCORRECT BATTERY
POLARITY WILL CAUSE DAMAGE TO UNIT.
BATTERY
NEGATIVE
BATTERY
POSITIVE
AC GROUNDS
(BEHIND COVER)
AC
OUT
AC
IN
30A
AC INPUT
LINE 1
30A
AC INPUT
LINE 2
30A
INVERTER
AC OUTPUT
Wiring box cover must be in place during
use to reduce risk of injury to persons
REM BTS
DC Ground or
Grounding Electrode
Terminal. See
manual for more
information.
N
L1
L2
N1
L1
L2
N2
WARNING: INCORRECT BATTERY
POLARITY WILL CAUSE DAM AGE TO UNIT.
BATTERY
NEGATIVE
BATTERY
POSITIVE
AC GROUNDS
(BEHIND COVER)
AC
OUT
30A
AC INPUT
LINE 1
30A
AC INPUT
LINE 2
30A
INVERTER
AC OUTPUT
Wiring box cover must be in place during
use to reduce risk of injury to persons
REM BTS
DC Ground or
Grounding Electrode
Terminal. See
manual for more
information.
On/Off
Status
FREEDOM SW
xantrex
On/Off
Status
FREEDOM SW
On/Off
Status
FREEDOM SW
On/Off
Status
FREEDOM SW
L1
L2
NEUTRAL
GROUND
120 VAC
Loads
240 Vac
Loads
Inverter AC
Distribution Panel
120 VAC
Loads
Inverter AC
Distribution Panel
CLEAR FAULT
RESET
INVERTER
ENABLED
Inverter
On
AC/
Charge
Fault
FREEDOM SW INVERTER/CHARGER
STACKINGXANBUS INTERFACE
Vented Battery
Enclosure
12Vdc or
24Vdc
Vehicle Chassis
Ground
AC IN
CLEAR FAULT
RESET
INVERTER
ENABLED
Inverter
On
AC/
Charge
Fault
FREEDOM SW INVERTER/CHARGER
STACKINGXANBUS INTERFACE
WARNING: INCORRECT BATTERY
POLARITY WILL CAUSE DAM AGE TO UNIT.
BATTERY
NEGATIVE
BATTERY
POSITIVE
AC GROUNDS
(BEHIND COVER)
AC
OUT
30A
AC INPUT
LINE 1
30A
AC INPUT
LINE 2
30A
INVERTER
AC OUTPUT
Wiring box cover must be in place during
use to reduce risk of injury to persons
REM BTS
DC Ground or
Grounding Electrode
Terminal. See
manual for more
information.
WARNING: INCORRECT BATTERY
POLARITY WILL CAUSE DAM AGE TO UNIT.
BATTERY
NEGATIVE
BATTERY
POSITIVE
AC GROUNDS
(BEHIND COVER)
AC
OUT
30A
AC INPUT
LINE 1
30A
AC INPUT
LINE 2
30A
INVERTER
AC OUTPUT
Wiring box cover must be in place during
use to reduce risk of injury to persons
REM BTS
DC Ground or
Grounding Electrode
Terminal. See
manual for more
information.
xantrex
xantrex
NEUTRAL
GROUND
Main
Distribution Panel
30A
30A
I
N
P
U
T
O
U
T
P
U
T
AC
IN
N
L1
L2
N1
L1
L2
N2
I
N
P
U
T
O
U
T
P
U
T
AC
IN
N
L1
L2
N1
L1
L2
N2
I
N
P
U
T
O
U
T
P
U
T
AC
IN
N
L1
L2
N1
L1
L2
N2
I
N
P
U
T
O
U
T
P
U
T
30A
NOTE: Refer to the Installation Guide for wire gauge details.
NOTE: Refer to the Installation Guide for wire gauge details.
DO NOT USE INPUT L2 AND OUTPUT L2
IN STACKING CONFIGURATIONS.
DO NOT USE INPUT L2 AND OUTPUT L2
IN STACKING CONFIGURATIONS.
Master unit
Slave unit
network
terminator
network
terminator
SCP
AGS
Master unit
Slave unit
network
terminator
network
terminator
SCP
AGS