Owners Guide
Table Of Contents
22 Xantrex Lithium-ion Battery Owner's Guide
Hot Ambient Temperature
Operation
The Xantex Battery can operate up to 131°F(55°C) while
recharging or discharging the battery.
During hot temperature operation, if the internal cell temperature
reaches above the high operational range, the BMS will
disconnect the cells from the terminals until the internal
temperature has dropped 4°F(~2°C) below the cutoff point.
This prevents damage to the cells and the over cycling of the
BMS.
NOTE: Discharging and recharging the battery will produce a
limited amount of heat inside the battery. Be aware that in high
ambient temperature environments, repeated disconnections
are likely, especially if the battery is under high loads or
recharge current.
Disconnect Event/Error Clearing
Operation
The Xantex Battery will disconnect the internal cells from the
terminals under many conditions. Depending upon the event or
error, the battery will reset the event or error automatically
without any user intervention. Some additional errors can be
temporarily cleared by a quick button press >one (1) second. If
the error is not cleared during the temporary duration the battery
will go to error again. Finally, some errors require a full reboot of
the whole battery by removing all power sources, the 12-Pin
connector, and turning the battery OFF-to-ON.