User's Manual

Xantrex RV Series Inverter/Charger Owner’s Manual
2
10. Symbols used in this manual and on the inverter/charger are:
Chassis Phase AC Output AC Input
1. Tools required to make AC wiring connections: Wire strippers, 1/2" (13 mm) open-end wrench
or socket, Phillips screwdriver #2, Slotted screwdriver 1/4" (6 mm) blade.
2. This inverter/charger is intended to be used with a battery supply with a nominal voltage of 12
volts DC.
3. For instructions on shelf mounting, see ”Installation” on page 14. For battery installation and
maintenance: read the battery manufacturer's installation and maintenance instructions prior
to operating.
4. No AC or DC disconnects are provided as an integral part of this inverter. Both AC and DC
disconnects must be provided as part of the system installation. See SYSTEM SAFETY
WIRING REQUIREMENTS section of this manual.
5. No over-current protection for the battery supply is provided as an integral part of this inverter.
Over-current protection of the battery cables must be provided as part of the system
installation. See “DC Over-Current Protection” on page 16.
6. No over-current protection for the AC output wiring is provided as an integral part of this
inverter. Over-current protection of the AC output wiring must be provided as part of the
system installation. See SYSTEM SAFETY WIRING REQUIREMENTS section of this
manual.
7. DC GROUNDING INSTRUCTIONS: This inverter/charger should be connected to a
grounded, permanent wiring system. For most installations, the negative battery conductor
should be bonded to the grounding system at one (and only one point) in the system. All
installations should comply with all national and local codes and ordinances.
8. AC GROUNDING INSTRUCTIONS: This inverter/charger includes neutral ground switching
for the AC electrical system. The AC system must have the neutral isolated from the
grounding system throughout the load distribution circuits. AC generators must have the
neutral bonded to the grounding system when used with this inverter.