User manual
SCAN
Indicated by the LED labeled scn. Three
input signals from channels 2, 3 and 4 are
scanned (or selected) by the voltage in chan-
nel 1
set manually (by engaging offset in channel
1 and adjusting the attenuator), or it may be
an external signal plugged into the inputs of
channel 1, labeled scan. Two orders of scan-
ning are implemented.
The func a output offers the result of scan-
ning in a pendulum-like order, while func b
output delivers signals being selected in a cir-
SAMPLE AND HOLD
Indicated by the LED labeled s&h. This mode
offers two independent channels of full sam-
ple and hold operation. In this mode, channels
2 and 4 are the control channels (as indicat-
ed by the sh trg panel labels), while signals
or voltages in channels 1 and 3 are being
sampled, and the result of this sampling (a
stepped voltage) is available at the func a
and func b
The motivation of this setup is that besides
typical processing of external signals, it al-
lows sampling of manually controlled voltag-
es when offsets (either positive or negative) in
channel 1 and 3 are engaged.
channel 1
voltage
func a
output
func b
output
above 3V input 4 input 2
1V to 3V input 3 input 4
-1 to +1V input 2 input 3
-3V to -1V input 3 input 2
below -3V input 4 input 4
6
sample & hold mode
input
stepped
voltage
scan mode
func a out
input 1
input 2
input 3
input 4
scan outputs arrangement
sh trig input