Offset
If the temperatureinanarea of the room differs from
the set temperature, you can perform atemperature
offset. Press
MENU
.Select the menu item
using the setting wheel. Conrm with
OK
.
The degree setting ashes on the display.
Now set the desired temperatureoffset (from -5 to
+5 °C) using the setting wheel. Press
OK
.The
temperatureshown on the display does not change.
Window function
If you open awindow,causing the temperatureto
drop rapidly,the Wireless Radiator Controller /Timer
automatically closes the heating valve to save energy.
appears on the display.The Wireless Radiator
Controller/Timer resumes normal operation
afterwards. To set up this function, select .
Conrm with
OK
.First select the sensitivity using
the setting wheel ( =high sensitivity, >=
moderate sensitivity (default setting) >=low
sensitivity). Conrm with
OK
.
Now select the time (10 min (factory setting) -60
min) for which the valve should remain closed.
Conrm with
OK
.
Holiday function
Youcan specify aset temperaturefor the time
you areaway.The schedule you have set resumes
after the holiday period. Press
MENU
.Select the
menu item using the setting wheel. Conrm
with
OK
.(The case symbol appears on the
display.) Use the setting wheel to set the end time for
the holiday function =date for regular heating times
to resume). Conrm with
OK
.Then enter the time
and conrm with
OK
. ashes on the display.
Now set the temperatureand conrm with
OK
.
appears on the display.You can deactivate the
function with
MENU
.
Child protection
Youcan lock the Wireless Radiator Controller/Timer
toprevent unauthorised operation. To do so, press
and hold
OK
+ simultaneously for approx.
2sec. until the symbol ashes on the display.
Holding this combination again causes the symbol to
disappear and removes the lock.
Pause heating/close valve
Press
MENU
.Select the menu item using the
setting wheel. Conrm with
OK
.Use the setting
wheel to set the temperatureonthe display to
.The valve is now closed and operates without
aschedule. The once-weekly limescale prevention
function remains active. After the pause in heating,
switch to AUTOmode in the menu to resume the
schedule you have set.
All reset
Press
MENU
.Select the menu item using the
setting wheel. Conrm with
OK
. ashes;
conrm with
OK
.The Wireless Radiator
Controller/Timer is now in back to the state in which
it was delivered. Proceed as though you werestarting
up the device for the rst time.
The frost protection and limescale prevention
functions areautomatically active:
Frost protection function
If the temperaturefalls below 6°C, the Wireless
Radiator Controller/Timer opens the valve until the
temperatureclimbs above 8°C. This prevents the
radiator from freezing.
Limescale prevention function
To prevent limescale from forming in the radiator
valves, the Wireless Radiator Controller/Timer
performs alimescale prevention run once per week