User Manual XC Tracer Maxx Rev 01 23.2.2020
setVolume=2
There are four volume settings, 0-3. With this option you set the volume that the vario will
use for beeping. When beepOnlyWhenFlying=yes is set then the vario will be silent until you
fly. Once you’re flying the vario will beep with the volume that you have set. Remember
though, that you can change the volume during flight with a short press of the red button.
dampingFactor=0.00
Here you can set a damping factor fron 0 up to max 10. As soon as you set a damping factor
then the vario will react slower to changes in altitude.
ClimbToneOnThreshold=0.2
With this setting the vario will begin to beep when the climb rate is higher than 0.2m/s. When
you want to use a thermal sniffer then you can set ClimbToneOnThreshold=-0.5 for example.
In this case the vario will begin to beep when the sink rate is less than -0.5m/s. In this way
you can adjust the beeping tone so that you know when you’re flying in lifting air, despite the
fact that you’re actually sinking gently. This can be helpful to find and core thermals in weak
conditions.
ClimbToneOffThreshold=0.1
With this setting the vario will stop beeping when the climb rate is below 0.1m/s. You can
also use negative values here, for example -0.51m/s when you use a thermal sniffer.
SinkToneOnThreshold=-3.0
The sink tone will be activated when the sink rate is below -3m/s.
SinkToneOffThreshold=-3.0
The sink tone will be deactivated when the sink rate is less than -3m/s.
tone=-10.00,200,100,100
tone=-3.00,280,100,100
tone=-0.51,300,500,100
tone=-0.50,200,800,5
tone=0.09,400,600,10
tone=0.10,400,600,50
tone=1.16,550,552,52
tone=2.67,763,483,55
tone=4.24,985,412,58
tone=6.00,1234,332,62
tone=8.00,1517,241,66