User's Manual

Specifications
• Power Supply: DC
• Voltage Range: 5* – 16VDC
• Peak current: < 150 mA
• Average current: < 110 mA
• Temperature Range: -31C to 65C (-25F to 149F)
• Card Read Distance: Up to 3.0” (76.2 mm) – Distance can vary widely depending on installation
conditions and credential type.
• Cable Distance to Panel in Wiegand mode:
-500 ft. maximum @ 22 awg for 12 volt supply.
-*100 ft. maximum @ 22 awg for 5 volt supply.
• Information Output: Wiegand = up to 64 bits
• Regulatory Approvals and Standards:UL 294, ISO15693, ISO14443A, Europe: CE Listed.
FCC Statement
The FCC requires the following statement for your information: This device complies with Part 15
of the FCC Rules. Operation is subject to the following two conditions: (1) this device may not
cause harmful interference, and (2) this device must accept any interference received, including
interference that may cause undesired operation. This reader utilizes and radio frequency energy
and has been tested and complies with the limits of FCC testing. Changes, modifications or
disregard of proper installation instructions not expressly approved by XceedID Corporation is
strictly prohibited by the FCC and could void the user’s authority to operate the equipment.
For Canadian Users
This unit has been tested and meets all applicable Industry of Canada technical specifications:
• Operation is subject to the following two conditions: (1) this device may not cause interference,
and (2) this device must accept any interference, including interference that may cause undesired
operation of the device.
For European Union Users
This unit has been tested and determined compliant to the following European Standards:
• Safety (art 3.1.a): EN50130-4 (1995 W/A1: 98 & A2: 03)
• EMC (art 3.1.b): ETS EN 301 489-3 V1.4.1 (2002-8)
• SPECTRUM (art 3.2): EN 300 330-2 V1.3.1 (2006-4)
0976
Figure 1. XF1560P/XF1560CS4 wire connections
XF1560P XF1560CS4
Green Data 0 RS485A (F-Duplex)
White Data 1 RS485B (F-Duplex)
Orange Green LED Green LED
Brown Red LED Red LED
Red Power + DC (5-
16 VDC)
Power + DC (5-16 VDC)
Black Ground Ground
Tan Tamper Output
(External)
RS485Z (F-Duplex) /
RS485B (H-Duplex)
Pink Card Present RS485Y (F-Duplex) /
RS485A (H-Duplex)
Yellow Beeper Beeper
Gray,
Purple,
Blue
Not Used Not Used
Copyright © 2008, XceedID Corporation. All rights reserved. XceedID: Document No: 0541-03; Issue No. 1; 8/22/2008