All in One Printer User Manual

Notes:
If at any stage the scanning is not completed properly, click Reset
and scan again.
If an error occurs while you are scanning the chart, an alert message
appears. Click OK and rescan the chart.
8. Click Next.
9. To save the calibration table, perform one of the actions:
Select As default name to automatically name the
calibration table using the screening method, media type,
and date.
Select Save as to type your own name.
Note: It is strongly recommended that you include the media type, and
screening method in the calibration table file name.
10. Select the media type to which to apply the calibration table.
11. Click Finish.
Creating a calibration table using the X-Rite i1 spectrophotometer 21