Wireless charging case User manual
Preface Please read this user manual carefully before use. This user manual only applies to the wireless charging hearing aid series. Function: Charging, drying, sterilization, storage Input voltage: 5V 1.5A Input current: 0.8A Output current: 7-10mA Charging time: 3-3.
Operation 1. Connect the power a. Plug the smaller end into the charging port of the base b. Plug the larger end with the provided adaptor. c. Plug the adaptor into a power outlet.
2. Open the charging case 3. Place the hearing instrument a. The end with dome of the instrument face and near the light for better sterilization. b. Place the instrument in each sides of the crossbar in the case.
4. Close the case to start charging a. The transmitting end automatically detects the hearing aid placed on the charging area of the case via Bluetooth. The detection time is 5-10 seconds. b. Once detected, the light will shine blue and system start charging. c. Close the case NOTE: The case will also start the drying process after you close the case.
Charging indicator recognition ① charging indicator Charging Fully charged NOTE: Due to the inconsistency of their respective residual power, there is a certain difference in the time when the indicator turn green between two device.
② Sterilization indicator UV Light When all the machines placed inside the case are fully charged, the charging indicator will light green. Then turn on the UV light and start sterilization. The total sterilization time lasts 30 minutes. Fully charged NOTE: 1. If the case is not closed, the sterilization will not start. 2. Once you open the case during sterilization, the process will restart and lasts 30 minutes.
FCC Regulatory Information This device complies with Part 18 of the FCC Rules. This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) This device must accept any interference received, including interference that may cause undesired operation. Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules.
FCC Supplier’s Declaration of Conformity NewSound SBW01 NewSound Primo WA801 This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. Responsible Party in the USA: IMHEAR CORPORATION 2711 Curtiss St.
Xiamen NewSound Technology Co.,Ltd Address: 1st and 2nd floor, No.13 of Xiangyue Road, Torch Hi-Tech Industrial Development Zone, Xiang'An District, Xiamen, China. Email: sales@usnewsound.