94 www.xilinx.com MicroBlaze Processor Reference Guide
1-800-255-7778 UG081 (v6.0) June 1, 2006
Chapter 4: MicroBlaze Instruction Set Architecture
R
Notes
The instructions brli and brali are not available.
By default, Type BInstructionswill take the16-bit IMM fieldvalue and sign extendit to 32
bits to use as the immediate operand. This behavior can be overridden by preceding the
Type B instruction with an imm instruction. See the imm instruction for details on using
32-bit immediate values.
A delay slot must not be used by the following: IMM, branch, or break instructions. This
also applies to instructions causing recoverable exceptions (e.g. unalignement), when
hardware exceptions are enabled. Interrupts and external hardware breaks are deferred
until after the delay slot branch has been completed.