2. INSTALLATION
Basic install procedure in trailers:
Install the length of the door sensor parallel to the length of the trailer on the driver side of the roll up door on
the top panel. The push button side faces the driver side wall. Gore vent faces out into the cargo area, away from
the driver side wall.
1. Find an area 1.5 inches from the top of the roll-up door top panel and 1.5 inches away from the roll-up
door hinge.
2. Clean the surface for the door sensor with 50/50 Isopropyl alcohol or similar such as brake cleaner to clean
the surface.
3. Rough up the surface with #000 steel wool and/or a blow torch if the temperature is near 30 °F.
4. Peel back the VHB tape cover to apply and install the door sensor.
5. Push the door sensor button for two seconds and then release. The LEDs will begin to blink.
6. Push the button for six LED blinks. The LEDs will go off to indicate successful activation.