User's Manual

32
5.4 Low Power Sleep/Wake Configuration
Type
Syntax
Response
ASCII
Set
+XT:3017,<WT1>,<WT2>,<WMN>,<MWM>
$$<UID>,3017,<WT1>,<WT2>,<WMN>,<MWM>##
Read
+XT:3017?
$$<UID>,3017,<WT1>,<WT2>,<WNM>,<MWM>##
Parameter
Type
Description
<WT1>
Numeric
Pre-Alert Maximum Wait Time
Valid Range is 0 32767 (seconds)
Default Value is 1
<WT2>
Numeric
Post-Alert Wait Time
Valid Range is 0 32767 (seconds)
Default Value is 1
<WNM>
Numeric
Shutdown/Sleep Notification Time
Default Value is 0 (Disabled)
<MWM>
Numeric
Wake Mask
0: Disabled
1: Sleep Time
2: Motion Wake
4: Motion/No-Motion Periods & Thresholds
8: Daily Wake
16: Wake-Pin (Input1/Ignition)
32: External Power
64: Battery Good
5.5 Sleep Alarm
Type
Syntax
Response
ASCII
Set
+XT:5401,<ST>
$$<UID>,5401,<ST>##
Read
+XT:5401?
$$<UID>,5401,<ST>##
Parameter
Type
Description
<ST>
Numeric
Sleep Alarm Timer
Valid Range is 1 32767 (minutes)
1 Minute Increments
Default Value is 0 (Disabled)