Installation Manual

EXI HALO Installation Manual Rev 2.0
EXI Wireless Systems Inc. Page 13 June, 1999
3.1.4. SET CONTROLLER SWITCHES FOR NORMAL OPERATION
Flip open the Controller lid to set the switches inside for the desired operation.
Figure 8 – Controller Switch Identification
MODE SWITCH SETTING
Change switches to desired operating mode as outlined below.
Mode Controller Function Response
0 Test Mode
1 Patient Monitoring with DKX Alarm ends on its own – fixed maximum bypass time
2 Patient Monitoring with DKX Continuous alarm - fixed maximum bypass time
3 Patient Monitoring Alarm ends on its own – fixed maximum bypass time
4 Patient Monitoring Continuous alarm - fixed maximum bypass time
5 Article Surveillance – Protection Alarm ends on its own – bypass extended by new tag
6 Article Surveillance – Protection Continuous alarm - bypass extended by new tag
7, 8, 9 Reserved for Article Surveillance -
Monitoring
A Authorized Entry 4 second release
B Authorized Entry 8 second release
C Authorized Entry Keep released while tag in field
D,E,F No Function
Modes 1 and 2 will only allow Bypass when the field is clear of Tags and the user enters a se-
quence of key presses on the DKX as described in the HALO Operation Manual. Keypads are for
Article Surveillance and Patient Monitoring Modes 3 and 4. The Pinpad can be used with any of
the Modes.
OPTION SWITCH SETTING
“Mode”
“Option”
Switch
“Range Adjust”
J2: Relay function
1
2
Relay 1 = TIF
Relay 2 = TIC
1
2
Both TIF