Installation Manual

EXI HALO Installation Manual Rev 2.0
EXI Wireless Systems Inc. Page 14 June, 1999
With a HOST computer in the system, the recommended switch setting for the “Authorized Entry”
mode is Option 0 (No Tags are authorized). “Patient Monitoring” or “Article Surveillance”
modes should have Option 1 selected (All Tags will be stopped).
These settings let the HOST have complete control over which Tags are allowed access to or from
the protected areas. The following table shows the selected function for each switch position, de-
pending on the mode selected.
Digit Selection Structure: Tag Serial # consists of digits ABCDEF
Option
Switch
Function Patient Monitoring or
Article Surveillance
Authorized Entry
0 Don’t act on any Tags No Tags are stopped No Tags authorized
1 Act on all Tags All Tags will be stopped All Tags authorized
2 Tag Selection on digit A Selected Tags will be
stopped
Selected Tags authorized. -
“no tag” + door open =
alarm
3 Tag Selection on digit B Selected Tags will be
stopped
Selected Tags authorized. -
“no tag” + door open =
alarm
4 Tag Selection on digit C Selected Tags will be
stopped
Selected Tags authorized. -
“no tag” + door open =
alarm
5 Tag Selection on digit D Selected Tags will be
stopped
Selected Tags authorized. -
“no tag” + door open =
alarm
6 Tag Selection on digit E Selected Tags will be
stopped
Selected Tags authorized. -
“no tag” + door open =
alarm
7 Tag Selection on digit F Selected Tags will be
stopped
Selected Tags authorized. -
“no tag” + door open =
alarm
8 Tag Selection on digit A Select Tags allowed to
pass
Selected Tags authorized. -
“no tag” + door open is OK
9 Tag Selection on digit B Select Tags allowed to
pass
Selected Tags authorized. -
“no tag” + door open is OK
A Tag Selection on digit C Select Tags allowed to
pass
Selected Tags authorized. -
“no tag” + door open is OK
B Tag Selection on digit D Select Tags allowed to
pass
Selected Tags authorized. -
“no tag” + door open is OK
C Tag Selection on digit E Select Tags allowed to
pass
Selected Tags authorized. -
“no tag” + door open is OK
D Tag Selection on digit F Select Tags allowed to
pass
Selected Tags authorized. -
“no tag” + door open is OK
E, F No Option
RANGE SWITCH SETTING: