Operations Manual

EXI HALO Installation & Operation Manual 981-000003-000
EXI Wireless Systems 14 March 2000
Revision 2.0
5.3. SYSTEM CONNECTION
The figure below shows the details of connecting the various system components together for the HALO
system.
Figure 10 - Detailed System Diagram
RECEIVE
ANTENNA
RBC
FCC ID# HE7MAX
TRANSMIT OUTPUT
SEA #1
SEA #2
Made in Canada . . with care
Controller
by
Power
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
+24V DC Input
System Ground
+12V Out 200 ma
System Ground
Weigand 0/Data
Weigand 1/Gnd
System Ground
MagOut 24V 200 ma
Door Switch In
System Ground
Unlock In
Override In
Strobe In
N.O
COM
N.C.
N.O
COM
N.C
Relay #1 Relay #2
Alarm In
OFF ON
R2 Controller
RS+
RS-
GND
RS+
RS-
GND
R2 RECEIVER
DATA
COMM.
Made in Canada . . with care
12/24 VDC
GROUND
DATA 0
DATA 1
N/O 1
COM 1
N/C 1
N/O 2
COM 2
N/C 2
POWER
RELAY
1 2 3 4 5 6 7 8 9 10
DKX
Keypad
Optional
PS-24
Power
Supply
EXI ELECTRONIC SYSTEMS
Winnipeg, Manitoba (204) 788-1696
Made in Canada
PRODUCT
MODEL NO.
SERIAL NO>
ROAM II/TAGRRR
SEA-M
1118
Brn
RIM
Grn
Blk
Blu
Whi
Red
Yel
1 2 3
4 5 6
7 8 9
*
0
#
Grn
Blk
Blu
RIM
R2 TAP
PC Terminator
Box
PC to
Network Cable
RS-485
Weigand
Brn
Pin# Wire
Color
Function
3 Brown +12/24 V
4 Green System GND
5 Black Weigand 0/Data
6 Blue Weigand 1/Data
10 White Alarm In
12 Red Unlock In
13 Yellow Override In
14 Gray Strobe In
Factory
Wired
Factory
Wired
RS-485 Shielded Cable, 24 AWG
Maximum Capacitance 15 pf per foot
Example: Electro Cables FT-4 Part #5302452
Daisy Chain (Series) Configuration as much as
possible.
RS-485 Connector (To Halo
NetworkController Output)
DB9
R2
Receiver
Pin
Function Wire
Color
DB 25
1 +12/24V Brown 14
2 System GND Green 7
3 Data 0 Black 20
4 Data 1 Blue 22
TAP
Optional
PS-24
Power
Supply
Pin # Function
9 or 12 RS +
7 GND
22 or 25 RS -
RIM Pin-Out
Com
NOTE: Check all network
wiring before connecting
to the PC.
Enlarged
View
RS
+
Gnd
RS
-
Caution: Ensure appropriate
stranded cables are used for
Elevator Shafts due to the
continuous flexing they will
have to endure!
Factory
Supplied
Factory
Supplied
RS-485
Weigand
Factory
Supplied
Optional RS-485 Repeater
(Required for total cable length
of greater than 4,000 ft, and
highly recommended for isolation
of Halo Elevator Controller)
RS-485
Repeater
Halo Receiver Connector Pin-Out
Halo Controller Connector Pin-Out
Optional, to
Enhance
Coverage
Elevator System or
other devices
Function Type 1 Type 2 Type 3 Type 4
RS
+
Yellow Brown Black Red
GND Green Blue White Green
RS
-
White Red Red Black
RS-485 3-Conductor Cable Code
(All have same function, but 4 versions of wire color)
O
r
a
n
g
e
o
r
G
r
a
y