5.4. DOOR CONTROL
The controller chassis may be horizontally or vertically mounted, on a wall, ceiling or shelf and should be
mounted so that the front face panel is easily accessible. Since it is preferable to leave the RX antenna attached
directly to the controller, the exact location of the controller will affect the reception of the tags and should
only be finalized after setting up the field. The RX antenna should be positioned on a vertical plane for
maximum performance.
Figure 11 – Door Coverage
Mount the Keypad about 10’ away from door so that it can be used before entering the detection
field.
Maglock release should be hooked up to an unused auxiliary normally open contact from Fire
Alarm Panel.
5.5. LOCATION FOR SRA EXCITER ANTENNAS
One of the most important aspect of the entire installation is the correct positioning of the SRA Exciter
Antenna. The Antenna may be installed:
Ø above the doorway, laid flat on the dropped ceiling tile.
Ø dropped inside a wall cavity 4’ above the floor.
Ø on the side wall along the hallway 4’ above the floor.
Each field needs to be fully tested to ensure adequate coverage of the protected area.
HALO
Controller
Door Sense
Magnetic Switch
Keypad
Exciter Antenna
Mag-Lock
EXI ELECTRONIC SYSTEMS
Winnipeg, Manitoba (204) 788-1696
Made in Canada
PRODUCT
MODEL NO.
SERIAL NO>
ROAM II/TAGRRR
SEA-M
1118
Roam II & Tagrrr
RECEIVE
ANTENNA
RBC
FCC ID# HE7MAX
TRANSMIT OUTPUT
SEA #1 SEA #2
Made in Canada . . with care
Controller
by
Power
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20
+24V DC Input
System Ground
+12V Ou 200 ma
System Ground
Weigand 0/Data
Weigand 1/Gnd
System Ground
MagOut 24V 200 ma
Door Switch In
System Ground
Unlock In
Override In
Strobe In
N.O
COM
N.C.
N.O
COM
N.C
Relay #1Relay #2
Alarm In
OFF ON
D
e
t
e
c
t
i
o
n
A
r
e
a
~
1
0
'
RIM
TAP
To other
Devices
To Computer
Power