User's Manual
Installation Guide: Access Control Reader Installation Guide: Access Control Reader
Wiegand
In Integrated operation and Network operation, the ACR sends microchip information
in standard 26 bit format Wiegand. This is an unacknowledged one-way
communication. Third-party software that receives this data must ensure correct
reception.
RS232
An RS232 port provides connection to a PC running a terminal emulation program
such as HyperTerminal® which is shipped with the Microsoft® Windows® operating
system.
Set the terminal as follows: one stop bit, no parity, baud rate 19200.
This is an unacknowledged one-way communication. Third-party software that
receives this data must ensure correct reception.
System Integration
In network mode, the RS485 network is connected to an Area Controller Hub
Sub-Network. Be sure to record the serial number and location of the Access Control
Reader for node location entry. Refer to the system installation manual for system
installation and commissioning.
Installation and commissioning is completed by the competent contractor or a
competent facility personnel. Following commissioning, no user adjustments are
required at the Access Control Reader during operation.
Page 17 PN: 981-000293-000 R1.3
Figure 3: LF Field Shape and Dimensions
The microchip is typically implanted
in the middle of the upper right
arm. For the best Antenna
sensitivity, align the Center of LF
Field with the microchip. This is
shown in Figure 4 Antenna
Mounting Height and Position, where
the user’s middle upper arm is
aligned with the center of the LF
field.
Figure 4: Antenna Mounting Height and Position
Antenna
Extent of
Effective LF Field
2" = 5.08 cm
4" = 10.16 cm
4
"
2"
2"
Center of LF Field
Page 6 PN: 981-000293-000 R1.3