User's Manual
Installation Guide: Access Control Reader Installation Guide: Access Control Reader
Antenna Orientation
The Antenna is most effective when the long axis of the Antenna is parallel to the long
axis of the microchip.
Mount the Antenna so that the longest axis is vertical to the floor as shown in Figure 4
This mounting assumes that:
The person is standing upright; and,
The microchip is inserted with its long axis parallel to the arm.
Controller Module Location Considerations
Place the Controller Module so that it will be out of sight of the facility occupants.
Mount the Controller Module so that the panel with the wiring connector and LED is
accessible during installation.
Ensure that the Controller Module air vents are unobstructed.
Figure 5: Antenna Mounting Holes
Configuration
The ACR can be configured for either:
Network Mode; or,
Integrated Mode.
Network Mode
When operated in Network Mode, the ACR can work as part of a VeriGuard security
system.
Mounting Keyhole
Mounting Keyhole
Cable Entry
Mounting Hole
Mounting Keyhole
Page 7 PN: 981-000293-000 R1.3
Communication Overview
The ACR sends microchip identification numbers through the Wiegand and RS232
ports and communicates via an RS485 network.
RS485
As part of a VeriChip RFID system the ACR sends the microchip identification number
to the Hub and to the application server using VeriChip’s proprietary RS485
communication protocol. The VeriChip RFID system issues commands to the ACR and
other components based upon its inputs and configuration.
Table 5: Antenna Tuning Record
DIP Switch Number Current
1234 mA
OFF OFF OFF OFF
OFF OFF OFF ON
OFF OFF ON OFF
OFF OFF ON ON
OFF ON OFF OFF
OFF ON OFF ON
OFF ON ON OFF
OFF ON ON ON
ON OFF OFF OFF
ON OFF OFF ON
ON OFF ON OFF
ON OFF ON ON
ON ON OFF OFF
ON ON OFF ON
ON ON ON OFF
ON ON ON ON
Page 16 PN: 981-000293-000 R1.3