XOMI36G XOMI42G NEED HELP? Call our ventilation experts toll free al 800-966-8300 AVEZ-VOUS BESOIN D’AIDE ? Contactez nos experts au numéro gratuit 800-966-8300 ¿NECESITA AYUDA? Póngase en contacto con nuestros expertos a través del número gratis 800-966-8300 USA RANGE HOOD - User instructions F HOTTE DE CUISINE - Notice d’utilisation E CAMPANA EXTRACTORA - Manual de utilización
XO Hood Warranty Proof of original purchase date and invoice is needed to obtain service under warranty. What is covered Limited 2 Year Warranty. For 2 years from the original date of purchase, we will provide, free of charge, parts and service labor in your home to repair or replace any part of the hood that fails because of a manufacturing defect. The warranty is extended to the original purchaser for products purchased for ordinary home use in North America.
ENGLISH USA IMPORTANT SAFETY INSTRUCTIONS FOR RESIDENTIAL USE ONLY READ AND SAVE THESE INSTRUCTIONS PLEASE READ ENTIRE INSTRUCTIONS BEFORE PROCEEDING. IMPORTANT: Save these Instructions for the Local Electrical Inspectors use. INSTALLER: Please leave these Instructions with this unit for the owner. OWNER: Please retain these instructions for future reference. Take care when using cleaning agents or detergents. Suitable for use in household cooking area.
Crepes Suzette, Cherries Jubilee, Peppercorn Beef Flambè). C. Clean ventilating fans frequently. Grease should not be allowed to accumulate on fan or filter. D. Use proper pan size. Always use cookware appropriate for the size of the surface element. E. Keep fan, filters and grease laden surface clean. F. Use high range setting on range only when necessary.Heat oil slowly on low to medium setting. G. Don’ t leave range unattended when cooking. H.
D. Ducted fans must always be vented to the outdoors. E. This unit must be grounded. WARNING - TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. WARNING - UNDER CERTAIN CIRCUMSTANCES DOMESTIC APPLIANCES MAY BE DANGEROUS. A. Do not check filters with hood working. B. Do not touch the lamps after a prolonged use of the appliance. C. No food must be cooked flambè underneath the hood. D. The use of an unprotected flame is dangerous for the filters and could cause fires. E.
Installation Preparation DUCT FITTINGS: This Hood Must Use an 6" Round Duct. It Can Transition to 3-1/4" x 10" or 3-1/4" x 12" Duct. Use this chart to compute maximum permissible lengths for duct runs to outdoors. NOTE: Do not exceed maximum permissible equivalent lengths! Maximum duct length: 100 feet for range hoods. Flexible ducting: If flexible metal ducting is used, all the equivalent feet values in the table should be doubled.
NEVER exhaust air or terminate duct work into spaces between walls, crawl spaces, ceiling, attics or garages. All exhaust must be ducted to the outside, unless using the recirculating option. Use single wall rigid Metal ductwork only. Fasten all connections with sheet metal screws and tape all joints w/ certified Silver Tape or Duct Tape. INSTALL THE DUCTWORK: NOTE: To reduce the risk of fire, use only metal ductwork. 1. 2. 3. 4.
› Front of hood › Side of hood �������� ������� �������� �������������������������� �������������������� ��������� › Top of hood › Mounting height and clearance: ������� Hood Specifications Product dimensions and clearance XOMI36G - XOMI42G: ����������������� ��������� ��� -8-
Installation Instructions Installation - Vented to the outside 1. Installation: Remove the structure from the packaging and remove the 2 screws A to separatethe upper part from the lower part (Fig.1). - Position hole template on the ceiling paying attention that the arrow is positioned on the same side as the appliance controls (Fig.2). Make 4, Ø8 holes in the ceiling and drive in 3 screws without completely tightening them.
structure B (Fig.4). Adjust the height by referring to the amounts indicated in (Fig.5) and block it usingthe 8 screws G that are supplied (Fig.6). - Fix the flexible pipe to the prepared air evacuation hole (Fig.7). - Take the upper chimney piece and fix it to the structure using the 2 screws A (Fig.8). Join the lower chimney piece with the upper one and fix it carefully using adhesive tape L (Fig.9A). - Unscrew the 2 screws O, max 3 mm (Fig.9A). Insert the exhaust unit inside � � Fig.
� Fig.7 Fig.8 � � � � � � � �������� � � � Fig.
the structure paying attention that the previously unscrewed screws O, hook into the slots in the lower part as indicated in (Fig.9B). Drive in the 3 screws N (supplied)and tighten the 2 screws O (Fig.9B). - Fix the air evacuation pipe H (not supplied) onto the connection flange F (Fig.10). - Remove adhesive tape L and rest the lower chimney piece above the cooker hood (Fig.11). - If the cooker hood is supplied with a lower chimney piece that must be fixed � � Fig.10 � � Fig.12 Fig.11 Fig.
to the hood body with screws, remove the anti-grease filters from the hood by acting on the relevant handles (Fig.13). Then screw the lower chimney piece pipe to the inside of the hood, using screws P (Fig.12). Relocate the filters in their seat. IMPORTANT - The range hood must be secured to wall studs or use drywall anchors capable of supporting 75 lbs.
POWER SUPPLY: IMPORTANT – (Please read carefully) WARNING: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. Remove house fuse or open circuit breaker before beginning installation. Do not use an extension cord or adapter plug with this appliance. Follow National electrical codes or prevailing local codes and ordinances.
2. CONNECT ELECTRICAL: WARNING - TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: Before making electrical connections to power supply, the electrical box must be secured in place as indicated in Fig.14. Before installing the appliance fix the electrical box as indicated in Fig.14. � � Fig.14A: Lift the electrical plant box. Fig.14B: Remove the 3 fixed screws. � Fig.
• Power Supply Connection: For connection to the power supply refer to the following Fig.15: 1. Remove the power supply cover by undoing the (2) screws (Fig.15A). 2. Break through the hole on the box cover. 3. Secure the power supply conduit to the cover. 4. Connect the wires of the hood to those of the power supply as described Fig.15B: BLACK = L line WHITE = N neutral GREEN/YELLOW = G ground - A double-pole switch properly rated must be installed to provide the range hood power supply disconnection.
- Carry out the power supplly connection in accordance with the national electric code, ANSI/NFPA 70-1999. 5. Insert the wires into the box, then close the box cover, securing it using the screws that were previously removed. The appliance must be installed at a minimum height of 27" from an electric cooker stove, or 32" from gas or combined cooker stoves. If a connection ductwork composed of two parts is used, the upper part must be placed outside the lower part.
Ductless Recirculating Option: � � � Carbon filter kit XORFK01: The kit includes an air diverter A, 1 screw B and 2 rectangular filters C. ��� � ��� � � Fig.1: Put together the two parts of the air deviator as shown in picture no 3.1. It may be necessary to cut the deviator to fit the width of the chimney as shown in picture 3.2. A sharp blade or Hacksaw is recommended to trim the plastic. - 18 - � Fig.2: To remove the two screws E, to take down the lower chimeny F.
� � � � � � � 6" Round Flexible Metal Duct Pipe Not Included Fig.3: To fix the air diverter A on the support’s bracket using the screw B as it is shown in the figure. Once that the air diverter A has been fixed, it is necessary to connect the flexible pipe (6" Round Flexible Metal Duct Pipe Not Included). Fig.4: To take the upper chimeny F and to fix it to the structure using the two screws E. � � � � 6" Round Flexible Metal Duct Pipe Not Included Fig.
� � � � Fig.7: Remove the aluminum panels by pulling the lever 1 out and pushing downwards 2. Fig.8: The charcoal filters C must be fitted in the ducting unit located inside the hood. � � � � Fig.9: Put the aluminum panels back in place (Fig.7).
USE • If the apparatus is equipped with the following controls luminous: A = LIGHT B = OFF C = SPEED I D = SPEED II E = SPEED III F = AUTOMATIC STOP TIMER - 15 minutes (*) � � � � � � • If your appliance does not have the INTENSIVE speed function, press key E for two seconds and it will be activated for 10 minutes after which it will return to the previously set speed. When the function is active the LED flashes. To interrupt it before the 10 minutes have expired press key E again.
MAINTENANCE • We recommend that the cooker hood is switched on before any food is cooked. We also recommend that the appliance is left running for 15 minutes after the food is cooked, in order to thoroughly eliminate all contaminated air. The effective performance of the cooker hood depends on constant maintenance; the anti-grease filter and the active carbon filter both require special attention.
- DO NOT allow deposit to remain for long periods of time. - DO NOT use ordinary steel wool or steel brushes. Small bits of steel may adhere to the surface causing rust. - DO NOT allow salt solutions, disinfectants, bleaches, or cleaning compounds to remain in contact with stainless steel for extended periods. Many of these compounds contain chemicals with may be harmful. Rinse with water after exposure and wipe dry with a clean cloth.
FUSE • The halogen lamps circuit is controlled by a fuse 5x20 mm, 125V 5A. In case of necessity it can be replaced only by specialized personnel. • Replacing halogen light bulbs: To replace the halogen light bulbs B, remove the glass panel C using a lever action on the relevant cracks. Replace the bulbs with new ones of the same type. Caution: do not touch the light bulb with bare hands.
XOMI36G - XOMI42G: ��� �� ��� �� ��� �� ��� ��� ��� �� ��� ��� ��� ��� ��� �� ��� �� �� ��� - 25 - ���
OPTIONS AND ACCESSORIES: Model XORFK01 - Ductless Recirculating Filter Kit. Model XOEDCMI - Duct Cover Extension. This accessory is available for installation with ceiling heights above 9 ft to 10 ft.
INSTALLATION PREPARATION: Check installation hardware: Locate the hardware package packed with the hood and check contents.
XOMI Spec Sheet Model: XOMI36G - XOMI42G Sizes: 36"- 42" Depth: 23-5/8" Features and Benefits: - 600 CFM high velocity blower optimally removes Smoke, Grease and Odors. - 3+1 speed electronic illuminated controls. - Four 20W Halogen Lights - Provide brilliant illumination over the cooking surface. - High quality Stainless Steel with incomparable handcrafted Italian finish. - Aluminum Mesh Filters - Trap airborne smoke and grease particles. They can be easily be removed for dishwasher-safe cleaning.