Installation and maintenance instructions DX100 Standard DX100PC Pull Cord DX100T Timer DX100H Humidistat DX100HP Humidistat and Pull Cord DX100PIR Integral Body Movement Sensor DX100VTD Delay Timer Toilet/Bathroom 100mm/4" Fan Range Retain for future reference GB F D NL I S GR N SE A ®
D A DX100PIR E m 5m 12 B F C G m 5m 11 2
H J DX100H & DX100HP I K DX100T DX100PIR L 3
GB Xpelair Toilet/Bathroom Fans DX100, DX100PC, DX100T, DX100H, DX100HP DX100PIR & DX100VTD installation & operating instructions Please leave this leaflet with the fan for the benefit of the user Installing the fan What the installer will need These appliances are intended for connection to fixed wiring. Check that the electrical rating shown on each fan matches the mains supply.
airflow across the room (e.g. opposite the internal doorway). Near the source of steam or odours. • • Not where ambient temperatures are likely to exceed 50˚C. • If installed in a kitchen fans must not be mounted immediately above a cooker hob, or eye level grill.
GB Xpelair Toilet/Bathroom Fans DX100, DX100PC, DX100T, DX100H, DX100HP DX100PIR & DX100VTD installation & operating instructions Please leave this leaflet with the fan for the benefit of the user 3. If the shaft has cavity wall, use the wall tube to bridge the cavity. 4. Fit ducting and condensation trap if necessary, positioning condensation trap as near to the fan as possible. If installing in a ceiling 1. Check there are no buried pipes or cables in the ceiling/joists etc.
fuse for the appliance must not exceed 5A. DX100T only I • To adjust the over-run period turn the control (T) clockwise to increase and anti-clockwise to decrease. DX100H & DX100HP only J • Humidity operation is factory set at approx. 70% Relative Humidity (RH), but can be adjusted between 50% and 90% RH by control(H). • Time delay is factory set at approx. 20 mins, but can be adjusted by control (T). • Both controls are adjustable.