Air Scrubber Owner's Manual Model: AP-1500D Series, AP-1800D Series, AP-2500D Series (115V~, 60Hz) Read and save these instructions www.xpower.com | 1-(855)-855-8868 | info@xpower.com Index: NA-1-A40 Edition: 1.3.
Safety Instructions ! WARNING - READ AND SAVE THIS INSTRUCTIONS BEFORE USING THIS PRODUCT. The user of electrical products may create hazards that include, but are not limited to injury, fire, electrical shock. Failure to follow these instructions may damage and/or impair its operation and void the warranty. • Before operating, remove all packaging material and check for any damage that may have occurred during shipping or any missing items.
Parts Description Machine 7 8 9 10 1 2 11 12 13 14 15 16 17 19 20 21 18 22 6 23 24 25 26 27 28 29 35 3 4 30 32 31 33 34 5 English - 3
(1) (2) (3) (4) (5) (6) (7) Inlet Grille Cover Screw Inlet Grille Cover Handle Screw Rubber Pad Motor Inlet Grille Cover Time Meter* Motor Housing Fixator Assembly (8) Motor Fixator (9) Motor Right Housing (10) Heat Insulation Plate (11) Motor (12) Bushing (13) Fan (14) Motor Left Housing (15) Motor Control Circuit Board Assembly (16) Rivet Nut (17) Filter Fixator (18) Flange Nut (19) Handle Cover (20) Handle Tube (21) Housing (22) Air Quality Sensor Cover (23) Air Quality Sensor (24) Power Switch (25) S
Filters (Continued) MODEL NUMBER AP-1500D Series AP-1800D Seires AP-2500D Series NFS16 RP20 RP24 Second Stage Filter PF16 PF19 PF23 Third Stage Filter CF35 CF35-490 CF50-595 (Optional) HEPA300-406PV HEPA300-490PV HEPA300-PV First Stage Filter Fourth Stage Filter Items Included • Hex Screws x 2 • Nuts x 2 XXX Manual De Usuario (página 10) XXX Mode d'emploi (page 18) Model / Modelo / Modèle: (115V 60HZ) Read and save these instructions before use Lea y guarde estas instrucciones antes
Installation and Operation Guide Remove Filter Package (If Any) Remove the packages of the filter before the first useage. Zero Setting • The accuracy of the pressure gauge might be affected by transportation. • Before the first usage, you should zero the pressure gauge in order to ensure the accuracy of the measurement.
Installing the Handle 1 4 1 2 3 (1) Screw off the hex screw with a hex screw driver on the inlet grill cover。 (2) Take out the inlet grill cover. (3) Put the screws through the holes on handle and the back of the machine housing. (4) Fasten the screws with the nuts from the inner surface of the machine.
Extension Setup (Optional) Exhaust Ducting • Turn off the machine. • Attach the ducting hose to the exhaust. Selecting a Location (Important) • Enclosed Area: For optimal efficiency and longer filter lifespan, the Air Scrubber should be operated in an enclosed area. Keep all doors, windows and other outside entrances to the room closed. • Air Circulation: It’s suggested to have a constant efficient air circulation inside your working area.
Control Panel Activity Indicator Air Quality . ESS Setting Button HOURS TO Time Meter Circuit Breaker 300 200 0 500 MAX OFF 0 40 10 0 Air Quality Monitor RESET PR Good Moderate Poor MIN Air Quality Sensor Power Switch Speed Switch Pressure Gauge Air Quality Monitor • When this monitor blinks, it indicates the Air Quality Sensor is now preparing for detection. • The digital display will show the concentration of fine particulate matter (PM2.5) in the environment in μg/m3.
Control Panel (Continued) Time Meter (For Model AP-1500DM, AP-1800DM and AP-2500DM Only) • The time meter contains 3 meters. Press the setting button to switch the meters. • The master meter shows the total running time from the first usage to the current moment. The value of the master meter can’t be reset. • The value of meter 1 and meter 2 can be reset. Press the setting button up to 5 seconds to reset the value. • When the fan turns on, the activity indicator will blink.
Transportation Transport with Trolley Handle Trolley Handle Exhuast Wheels • Press down the trolley handle to tilt up the air scrubber on the wheels. • Push forward to transport with the trolley handle. User Maintenance Instructions Frequent maintenance is recommended on this appliance. Failure to follow the maintenance instructions may cause failure of the appliance and void the warranty. Before performing any maintenance or cleaning, always disconnect the Air Scrubber from its power source.
Machine Maintenance • When not in use, unplug, and uninstall power cords and all the extensions. Store the appliance in a dry and cool indoor place. Make sure it’s out of reach of children. • Use a damp cloth to wipe the surface of the housing. Do not clean the unit with water directly. • Check if the grille covers are clean. Remove dirt or any other objects that could block the air inlet and air outlet.
Filter Maintenance To ensure the best filtration efficiency and to prevent secondary pollution of used filters, you should replace or clean the filters frequently or when the filter clean/change light illuminates. Please follow the instructions below. Unload the filters (See Also Page 3: Parts Description) • Screw off the screw on the inlet grill cover and take out the inlet grill cover. • Screw off the 4 screws on sides, and release the filter fixator. • Then you could unload the filters from the top.
Filter storage • When not in use for a long time, you should store the filter separately from the machine. • Always clean the filters before storage. Place the filters in a sealed plastic bag and store it in a dry and cool indoor place. Replace the filters periodically • Even if the pressure gauge shows negative pressure is still lower than the values below, it’s suggested to check and replace the filters every 6 months.
Troubleshooting Guide PROBLEM Air Scrubber does not start POSSIBLE CAUSE SOLUTION No electricity. Check for power supply. The power cord is not properly plugged in. Remove and reconnect the power cord. The circuit breaker on the additional electrical receptacle (Daisy chain) trips. Remove all appliances on the additional electrical receptacle and press circuit reset button. Unit runs but no or very low air movement Air outlet is blocked. Remove blockage. Filters are fully loaded.
Technical Specification Machine Specification MODEL NUMBER AP-1500D Series Voltage/ Frequency Amperage Rated Airflow Unit Dimension (L) x (W) x (H) Unit Weight English - 16 AP-2500D Series 115 V~, 60 Hz 1.5 A 3.5 A 8.0 A 700 CFM 1100 CFM 1800 CFM Speed Control Cord Length AP-1800D Series Variable Speeds 13 ft. / 4.0 m 25 ft. / 7.6 m 49.3 x 55.5 x 91 in. / 19.4 x 21.9 x 35.8 cm 57.4 x 63.9 x 94.6 in. / 22.6 x 25.2 x37.2 cm 29.4 x 26.7 x 38.8 in. / 74.8 x 67.8 x 98.6 cm 45.9 lbs / 20.
Filter Specification FILTER MODEL NUMBER Type of Filter Size Thickness NFS16 Nylon Mesh Filter 16 x 16 in. - 20 x 20 in. 1 in. 24 x 24 in. 1 in. 16 x 16 in. 0.8 in. 19 x 19 in. 1.4 in. PF23 23 x 23 in. 1.8 in. CF35 16 x 16 in. 1.4 in. 19 x 19 in. 14 in. CF35-595 23 x 23 in. 14 in. HEPA300406PV 16 x 16 in. 11.5 in. 19 x 19 in. 11.5 in. 23 x 23 in. 11.5 in.
XPOWER Limited Warranty (USA) 1 YEAR LIMITED WARRANTY XPOWER-branded products purchased in the U.S. from authorized distributors include a 1-year limited warranty. Contact XPOWER to confirm warranty information about your product(s). This limited warranty covers defects in materials and workmanship in your XPOWERbranded products, purchased in the U.S. ONLY. Local warranty policy (if any) in your country will cover products purchased outside the U.S.
If you are instructed to return the unit for service or replacement, please: (1) Request a RMA (Return-Merchandise-Authorization) number. (2) Use the original or an equivalent packaging, prepay shipping charges at your own expense to the address provided by XPOWER, with the RMA number on the shipping label or the packaging. (3) Include all the original parts and components. XPOWER will inspect, assess and advise the repairs needed and applicable cost, if any.
XPOWER Manufacture, INC. 668 S. 6th Ave., City of Industry, CA 91746 USA www.xpower.com | 1-(855)-855-8868 | info@xpower.com Read and save these instructions Index: NA-1-A40 Edition: 1.3.