CT F/C °C %RH TOTAL TIME : Low Grain Refrigerant Dehumidifier Owner's Manual Model: XD-75L, XD-75LH, XD-85L, XD-85LH (115V 60HZ) Read and save these instructions before use www.xpower.com | 1-(855)-855-8868 | info@xpower.com Index: NA-1-A1 Edition: 1.5.Final ENERGY STAR® qualified units remove moisture with less energy than conventional dehumidifiers. This does not apply to all models mentioned in this manual.
Safety Instructions ! WARNING - READ AND SAVE THIS INSTRUCTIONS BEFORE USING THIS PRODUCT. The user of electrical products may create hazards that include, but are not limited to injury, fire, electrical shock. Failure to follow these instructions may damage and/or impair its operation and void the warranty. • Before operating, remove all packaging material and check for any damage that may have occurred during shipping or any missing items.
LGR Dehumidifier Introduction • XPOWER LGR (Low Grain Refrigerant) Commercial Dehumidifiers are designed to maximize water extraction while combining the highest efficiency in performance and portability. • Latest technology and a high efficiency extraction process ensures peak performance in even the most challenging environments, such as extreme temperature and low environment humidity.
Parts Description Secondary Intake Cover Secondary Filter FRONT Hand Carry Handle Hand Carry Handle Trolley Handle* Primary Intake (Grille) Secondary Intake Power Outlet Wheels* Primary Filter Rear Hand Carry Handle Control Panel Trolley Handle* Hand Carry Handle Hangers Exhaust (Grille) Drainage Outlet Wheels* * Trolley handle and wheel feature do not apply to all models mentioned in this manual.
Installation and Operation Guide Selecting a Location (Important) • Positioning: Before using the dehumidifier, place the unit UPRIGHT for at least 1 hour before use to allow the refrigerant to stabilize. If the unit was tilted on its side or upside-down during transportation, set the unit UPRIGHT for at least 4 hours before use. The dehumidifier must be positioned UPRIGHT on a level surface during use. • Enclosed Area: For optimal efficiency, the dehumidifier must be operated in an enclosed area.
Installation and Operation Guide (Continued) Power Cord Installation Primary Intake Power Cord • Connect the plug connector on the power cord to the power outlet of the machine. Drain Hose Installation Control Panel Hanger • Attach the drain hose inlet to the drain outlet of the machine. • The machine’s outlet can be found as the graph on the left. Drain Hose Press to Install/Release English - 6 • Please have a separate container to collect the water coming from the other end of the drain hose.
Installation and Operation Guide (Continued) Trolley Handle Installation* * Trolley handle feature does not apply to all models mentioned in this manual. Hand Carry Handle • Slide the trolley handle under the hand carry handle and in front of the secondary intake. Secondary Intake Primary Intake Top View Hex Key Threaded Holes Threaded Holes Internal Hex Screws Trolley Handle • Align the screw holes on the trolley handle to the threaded holes on the housing.
Installation and Operation Guide (Continued) Extension Setup (Optional) ① ② ③ Intake Ducting ① Install the intake adapter*. ② Screw on the four screws. ③ Attach adapter. the ducting hose to the intake *The intake adapter is sold separately. ② ①, ⑤ ③ ④ Exhaust Ducting (Lay Flat) (12 inch/30.5 cm Diameter) ① Screw off the four screws. ② Take out the ducting frame. ③ Let the ducting hose go through ducting frame. English - 8 ④ Turn the the ducting hose around the frame to its back.
Installation and Operation Guide (Continued) Control Panel Power Control Temperature Display Fan Speed Manual Drainage Evaporator Coil/ Environment Temperature Switch CT °C F/C Fahrenheit/Celsius Scale Switch %RH Relative Humidity Display TOTAL TIME : Humidity Control Total Running Time Buttons Manual Drainage Press to drain manually. Manual drain will °C CT last°Cfor 3 minutes (180 seconds).
Installation and Operation Guide (Continued) Control Panel (Continued) Temperature °C CT Display TOTAL TIME This will show the temperature of the evaporator or environment (See Page 9: : %RH Evaporator Coil/Environment Temperature Switch). WhenCT in Celsius scale, °C will TOTAL TIME F/C be illuminated. When inCT Fahrenheit scale, °C will turn off.
Installation and Operation Guide (Continued) Start Your Job Turn on the dehumidifier Press the Power Control button to switch on the machine. You may see the dehumidification light is flashing. Please wait for 3 minutes (180 seconds) until the machine completes the startup. °C CT Write down the starting time RH Please remember to write down the starting% time F/C the usage time.
Installation and Operation Guide (Continued) Start Your Job (Continued) Secondary Intake (Open) Secondary Intake Cover Secondary Intake (Closed) ! Important: Close the secondary intake when environment temperature falls under 64 °F (18 °C) or in contaminated environment for better efficiency • Take out and flip the secondary intake cover along the short edge. • Reinstall the secondary intake cover. The secondary intake is now covered.
Installation and Operation Guide (Continued) Start Your Job (Continued) Turn off the dehumidifier Press the Power Control button to switch off the machine. When turned off, the machine will automatically process drainage for 75 seconds. Please wait until this process completes. Transportation Before transportation, you should always: • Process a drainage manually. Otherwise the water may spill and enter in core parts of the machine during transportation. This may also void the warranty.
User Maintenance Instructions Frequent maintenance is recommended on this appliance. Failure to follow the maintenance instructions may cause failure of the appliance and void the warranty. Before maintenance or storage, you should always: • Process a drainage manually. • Disconnect the machine from the power source. • Remove all the extension setup. Organize the Power Cord and Drain Hose Control Panel Hanger • Remove the power cord/ drain hose from the outlet of the machine.
User Maintenance Instructions (Continued) Clean the surface • Use a damp cloth to wipe the surface of the housing. Do not clean the unit with water directly. • Do not clean the fins of the evaporator and condenser by yourself. Store the machine • Store the appliance in a dry and cool indoor place, away from direct sunlight as well as chemicals and out of reach of children. • IMPORTANT: make sure the machine is levelly positioned.
Troubleshooting Guide PROBLEM (Continued) POSSIBLE CAUSE Dehumidifier runs The machine was tilted and but humidity level wasn’t positioned upright for does not decrease enough time before use. SOLUTION Position the machine upright on a level surface and wait for at least 4 hours before next use. The air filter or air inlet/outlet is Remove blockage. blocked. The environment temperature is too low/high or the humidity level is too low.
Technical Specification MODEL NUMBER XD-75L XD-75LH Voltage / Frequency XD-85L XD-85LH 115 V~60 Hz Amperage 6.3 A 6.7 A Operation Temperature/ Relative Humidity Requirement 33 °F - 105 °F (0.6 °C to 40.6 °C) / 20% RH or higher Rated Airflow 170 CFM 180 CFM Speed Control Automatic Water Removal Efficiency 105 °F (40.6 °C) / 20% RH 19 Pints (9.0 L) per day 22 Pints (10.4 L) per day Water Removal Efficiency 80 °F (26.
XPOWER Limited Warranty (USA) 1 YEAR LIMITED WARRANTY XPOWER-branded products purchased in the U.S. from authorized distributors include a 1-year limited warranty. Contact XPOWER to confirm warranty information about your product(s). This limited warranty covers defects in materials and workmanship in your XPOWERbranded products, purchased in the U.S. only. Local warranty policy (if any) in your country will cover products purchased outside the U.S.
XPOWER Limited Warranty (USA) (Continued) If you are instructed to return the unit for service or replacement, please: (1) Request a RMA (Return-Merchandise-Authorization) number. (2) Use the original or an equivalent packaging, prepay shipping charges at your own expense to the address provided by XPOWER, with the RMA number on the shipping label or the packaging. (3) Include all the original parts and components. XPOWER will inspect, assess and advise the repairs needed and applicable cost, if any.
XPOWER Manufacture, INC. 240 Clary Avenue San Gabriel, CA 91776 USA www.xpower.com | 1-(855)-855-8868 | info@xpower.com Read and save these instructions before use Index: NA-1-A1 Edition: 1.5.