3.3.4.1 Absolute Maximum Rating MTw
Shock (any axis)
TBD
Input Voltage
-0.3 V … 6 V (note power is supplied only via USB)
Temperature During operation
-10 oC - +60 oC
Temperature During charging
0
o
C - +45
o
C
3.3.4.2 Absolute Maximum Rating AWINDA Station
DC Input Voltage
-0.3 V … 16 V (Use included DC adapter)
SYNC (BNC) inputs
-0.5 to 3.8V
Operating Temperature
-20
o
C - +80
o
C
Exposure to absolute maximum rating conditions for extended periods may affect device
reliability.
NOTE: Drops onto hard surfaces can cause shocks of greater than 20000 m/s2 (2000 g)
exceeding the absolute maximum rating of the device. Care should be taken when handling
to avoid damage. Drops causing shock greater than absolute maximum ratings may not
destroy the device but will permanently alter the properties of the physical motion sensors,
which may cause the device to become inaccurate. If this occurs, please contact
support@xsens.com to investigate if the MT should be returned for a check.
3.3.5 Keeping the Hardware Clean
The housing of the MTw and Awinda Station are waterproof. However, the housing is not
watertight. To keep the Awinda Station and the MTw’s clean, use a damp cloth to wipe the
surfaces.