User's Manual

Document MV0319P.N
© Xsens Technologies B.V.
MVN User Manual
23
5.7.7 Awinda Station Status LED
The Awinda Station has five LED indicators. From right to left, these indicators are:
LABEL
LED
DESCRIPTION
CHRG
[CHaRGer
functionality]
OFF
When no mains power supply is connected to the Awinda Station.
GREEN: When 12V power supply is connected (mains power supply).
STAT
[STATus of
the Awinda
Station]
OFF
OFF: When no power supply is present and when MVN Studio is not started.
Power is from mains power supply and / or USB.
GREEN: Both USB connection present and MVN Studio running connected
to driver.
ORANGE: USB connection to host PC is present.
RED: Only power supply connected or error has occurred, e.g., a short-
circuit of an MTw.
EXT
[EXTernal
connection]
OFF
Remains off unless external connection made.
GREEN: External connection e.g. sync port.
CONN
OFF
OFF: No wireless connection.
GREEN slow blinking: (1 blink per second), radio switched on. When MTw
connects, MTw LED and CONN LED blink synchronously.
Fast blink: Measurement Mode.
DATA
OFF
OFF: No data received.
GREEN: Measurement mode.
ORANGE: Flushing. Flushing is the action of transferring data that has been
stored on the MTw buffer, while the MTw was out of range and unable to
transfer data in real-time to the Awinda Station.
RED: Recording mode is active. This allows the remote monitoring that the
host PC has initiated a recording successfully.
Note:
The power supply is needed to charge docked MTw’s or to change between power off and power on, of
docked MTw’s. Only the power supply is needed for charging purposes (USB is not needed in this case).
Power supply and USB connection are required for firmware updates or location reassignment of MTw’s.