8 Setup
The setup workflow stage consists of three parts; input the subject’s body dimensions, data fusion and
sensor to segment calibration. The calibration procedures are only available once the MVN system is
connected and the 3D Character has appeared in the view port.
When a file has been recorded this icon remains active to enable changes to body dimension inputs.
NOTE: It is not possible to save a calibration file, when a recorded file is open.
The following steps are described for single system calibration. If multi-person capture is enabled, each
step should be repeated for each additional system.
8.1 Body Dimensions
A)
B)
Figure 30: Input body Dimensions of test subject. A) Single subject capture B) Two subject capture
Figure 30 shows the interface for inputting the subject dimensions prior to a sensor to segment
calibration. It is necessary to input body height and foot length (shoe length at the time of the
measurement) in order for MVN Studio to calculate other segment lengths (based on an anthropometric
model). A recording cannot be performed if the user does not insert these values; instead the
following error is generated:
5
5
Note that a recording can be performed without prior insertion of body dimension and without a calibration, if the
feature “Allow uncalibrated recording” is enabled in the preferences menu.