.5 HP 5280 GPH CSA IN GROUND POOL PUMP ITEM: 75034 OWNER’S MANUAL AND SAFETY INSTRUCTIONS SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER).
IMPORTANT SAFETY INFORMATION GENERAL SAFETY WARNINGS Read all safety warnings and instructions. Failure to follow the warnings and instructions may result in electric shock, fire and/or serious injury. Save all warnings and instructions for future reference. The warnings, precautions, and instructions discussed in this instruction manual cannot cover all possible conditions and situations that may occur.
IMPORTANT SAFETY INFORMATION Failure to bond pump to pool structure will increase risk for electrocution and could result in injury or death. To reduce the risk of electric shock, see installation instructions and consult a professional electrician on how to bond pump. Also, contact a licensed electrician for information on local electrical codes for bonding requirements. Use a solid copper conductor, size 8 or larger. Run a continuous wire from external bonding lug to reinforcing rod or mesh. Connect a No.
IMPORTANT SAFETY INFORMATION Hazardous Pressure: Pool and spa water circulation systems operate under hazardous pressure during start-up, normal operation, and after pump shut-off. Stand clear of circulation system equipment during pump start-up. Failure to follow safety and operation instructions could result in violent separation of the pump housing and cover due to pressure in the system, which could cause property damage, severe personal injury, or death.
PRODUCT INFORMATION TWO-SPEED PUMPS Two-speed models are recommended in a swimming pool when high speed is needed for maximum filtration at peak periods and whenever turbidity levels are high. At other times, switch to low speed. For backwashing and vacuuming, high speed is required. In spas and hot tubs, use high speed to attain full performance in the hydro-therapy mode. At other times, such as filter/heat cycle mode, use low speed.
PRODUCT INFORMATION PUMP HOUSING STRAINER BASKET STRAINER COVER PUMP HOUSING MOTOR MOUNTING FOOT PUMP COVER & GASKET TRAINER HOUSING Assembled Product Dimensions (L x W x H) 24.60 x 8.85 x 12.40 Inches 1.5 HP In-Ground Pump. Compatible with PL30-6 Filter Tank. Self-priming for in-ground functionality. Can be installed as 110V or 220V. Drain plug for easy winterizing. High durability with corrosion proof polymer Fittings connections: 1 1/2 inch. NPT Volt 110/220. Amps 15/7.5. 88 GPM, HMAX: 20 m.
INSTALLATION PUMP LOCATION Installing union connections at the suction and outlet ports is recommended, to facilitate servicing of pump and to allow for indoor storage during the winter months. Use Teflon tape to seal threaded connections on molded plastic components. All plastic fittings must be new or thoroughly cleaned before use. NOTE: DO NOT use Plumber’s Pipe Dope as it may cause cracking of the plastic components.
INSTALLATION Insure that the electrical supply available agrees with the motor’s voltage, phase, and cycle, and that the wire size is adequate for the (KW) rating and distance from the power source. NOTE - All electrical wiring MUST be performed by a licensed electrician, and MUST conform to local codes and NEC regulations. Use copper conductors only. Risk of Electric Shock. All electrical wiring MUST be in conformance with applicable local codes, regulations, and the National Electric Code (NEC).
START UP PRIOR TO START-UP Notice: It is necessary to perform a pressure test prior to initial use to ensure pump is functioning properly. The following criteria should be maintained for this test: 1. Have a professional perform this test. 2. Ensure all pump and system components are sealed properly to prevent leaks. 3. Remove any trapped air in the system by fully opening filter manual air relief valve until a steady stream of water is discharged. 4.
OPERATION MAINTENANCE Clean strainer basket regularly. DO NOT strike basket to clean. Inspect strainer cover gasket regularly and replace as necessary. This pump has self-lubricating motor bearings and shaft seals. No lubrication is necessary. Keep motor clean. Insure air vents are free from obstruction to avoid damage. DO NOT use water to hose off motor. Occasionally, shaft seals must be replaced, due to wear or damage.
OPERATION SHAFT SEAL CHANGE INSTRUCTIONS 1. Shut off water flow to pump by closing appropriate valves or by plugging both the skimmer outlet port and return port to pool. Disconnect piping or hoses from the motor/pump assembly. 2. Remove the strainer by disengaging and removing the strainer cover. Remove the basket. Lift up on strainer ‘C’ clip and remove. Finally, slide strainer housing forward and remove. 3. Unscrew screws and remove pump cover, exposing the impeller. 4.
WIRING DIAGRAM This is how the pump should be wired when it is received. On the wiring diagram, you see the colors black and yellow pointing to the wiring locations. These spots are for pumps intenal black and yellow wires only. This is only used for reference in the instance that a wire comes off its post. Your wires attach where the diagram shows “line”. These are empty posts on the pump and cover. NEVER have your wire on the same post as an internal wire. TO ATTACH YOUR WIRES, FOLLOW THESE STEPS: 1.
TROUBLESHOOTING 12
MAINTENANCE Clean strainer basket regularly. DO NOT strike basket to clean. Inspect strainer cover gasket regularly and replace as necessary. Keep motor clean. Insure air vents are free from obstruction. Occasionally, shaft seals must be replaced, due to wear or damage.
OF NOTE PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT.