Use and Care Manual
5
PUMP LOCATION
INSTALLATION
Locate the system below the pool water line, for best pump performance. Install pump on a rm, level base 
or pad to meet all local and national codes. The eld supplied base or pad must be level. Though the pump 
is designed for outdoor use, it is strongly advised to protect the electrical components from the weather. 
Select a well-drained area, one that will not ood when it rains. Pump motors require free circulation of air 
for cooling. Do not install pump in a damp or non-ventilated location.
POOL 
RETURN
DRAIN 
VALVE
OUTLET 
VALVE
PUMP 
WITH 
STRAINER
POOL 
SUCTION
BALL 
VALVE
WATER LINE
1. Pump Mounting
Install pump on a rm, level base or pad to meet all local and national codes. Fasten pump to base or 
pad with screws or bolts to further reduce vibration and stress on pipe or hose joints. The base MUST be 
solid, level, rigid, and vibration free.
Pump mount must:
 Allow pump inlet height to be as close to water level as possible.
 Allow use of short, direct suction pipe (to reduce friction losses).
 Allow for gate valves in suction and discharge piping.
 Be protected from excess moisture and ooding.
 Allow adequate access for servicing pump and piping.
PIPE SIZING CHART
NOTE: It is recommended that a minimum length of piping, equivalent to 10 pipe diameters, be used 
between the pump suction inlet and any plumbing ttings.