3” TIMER SAND FILTER PLUS 3/4HP ABOVEGROUND SELF PRIMING POOL PUMP ITEM: 75159 OWNER’S MANUAL AND SAFETY INSTRUCTIONS SAVE THIS MANUAL: KEEP THIS MANUAL FOR SAFETY WARNINGS, PRECAUTIONS, ASSEMBLY, OPERATING, INSPECTION, MAINTENANCE AND CLEANING PROCEDURES. WRITE THE PRODUCT’S SERIAL NUMBER ON THE BACK OF THE MANUAL NEAR THE ASSEMBLY DIAGRAM (OR MONTH AND YEAR OF PURCHASE IF PRODUCT HAS NO NUMBER).
IMPORTANT SAFETY INFORMATION GENERAL SAFETY WARNINGS SERIOUS BODILY INJURY OR DEATH CAN RESULT IF THIS PUMP AND SAND FILTER IS NOT INSTALLED AND USED CORRECTLY. INSTALLERS, POOL OPERATORS AND POOL OWNERS MUST READ THESE WARNINGS AND ALL INSTRUCTIONS BEFORE USING THIS PUMP AND SAND FILTER. SAFETY Most states and local codes regulate the construction, installation, and operation of public pools and spas, and the construction of residential pools and spas.
IMPORTANT SAFETY INFORMATION Do not operate this product when pool is occupied. To reduce the risk of entrapment hazard, never enter the pool if suction strainer component is loose, broken, cracked, damaged or missing. Replace loose, broken, damaged, cracked or missing suction strainer components immediately. Never play or swim near suction fittings. Your body or hair may be trapped causing permanent injury or drowning.
IMPORTANT SAFETY INFORMATION POOL AND SPA PUMPS MOVE LARGE VOLUMES OF WATER, WHICH CAN POSE EXTREME DANGER IF A PERSON;S HAIR COMES IN PROXIMITY TO A DRAIN THAT IS NOT THE PROPER SIZE FOR THE PUMP OR PUMPS. The Virginia Graeme Baker Pool and Spa Safety Act imposes certain new requirements on owners and operators of swimming pools and spas.
SAFETY / FEATURES Always turn pump off before changing valve positions. Changing valve positions while the pump is running can damage the control valve, which may cause serious injury or property damage. Chemical fumes and/or spills can cause serious corrosion to the filter and pump structural components. Structurally weakened components can cause filter, pump or valve attachments to separate and could cause serious bodily injury or property damage. High voltage can cause serious or fatal injury.
INSTALLATION PUMP LOCATION AND MOUNTING: • THE SYSTEM MUST BE INSTALLED ON A SOLID LEVEL AND VIBRATION-FREE BASE. • PROVIDE A LOCATION PROTECTED FROM THE WEATHER, MOISTURE, FLOODING AND FREEZING TEMPERATURE. • PROVIDE ADEQUATE ACCESS, SPACE AND LIGHTING FOR ROUTINE MAINTENANCE. • PUMP MOTOR REQUIRES FREE CIRCULATION OF AIR FOR COOLING. DO NOT INSTALL THE PUMP IN A DAMP OR NON-VENTILATED LOCATION. A TEAM OF 2 OR MORE PEOPLE IS RECOMMENDED FOR SETTING UP THIS PRODUCT. MOTOR PRE-FILTERING ASSEMBLY SETUP: 1.
INSTALLATION 1. Pump needs screw and cover to install on the filter drain. 2. Press and turn the sand tank to mount it to the sand filter support with correct direction, drain plug on the outside (see below) 3. Insert the tube with diffuser body inside the tank as above picture shows, then place the funnel on the tank’s mouth and out the quartz sand into the tank. A 12” sand filter requires about 19kg of sand to fill the tank, a 14” sand filler needs about 27kg of sand to fill the tank. 4.
INSTALLATION 5. Connect the sand tank to the pump with hose and hose adapters. INSTALLATION NOTES: Make sure the filter has worked under work pressure and using a pressure control valve when the system is using a booster pump. If the pump position is higher than the water level, it requires installation of the back water control valve. If the pump position is higher than the water level, it requires installing an isolation valve. It can stop the water return back when doing the general inspection.
INSTALLATION POWER CONNECTION Be sure to check whether used voltage is corresponding to the required voltage indicated on the nameplate label. The voltage for the motor should not exceed 10% or below the requirement on the requirement on the nameplate label. If too much voltage is applied, the motor will overheat and lead to overload trip and shorten the life of the component. All connections must be applied by a qualified technician. All wiring must comply with local and national and local laws.
OPERATION BUTTON INSTRUCTION ON / OFF BUTTON: Starts and stops the pump TIMER BUTTON: Set the desired operation period: 2h/4h/6h/8h/10h/16h/24h Depressing the Timer button more than 10 seconds the Single Cycle indicator light will flash. If the Timer Indicator light flashes in ‘24h’ this means the Single Cycle Indicator light did not work. Press the TIME button to adjust the time. The pump must be stopped, otherwise the time cannot be adjusted.
MAINTENANCE AND TROUBLESHOOTING Confirm the screws in the baseboard are installed tightly. If any are found, re-tighten them before use. Confirm the power cords are in good condition. If any parts are worn, cracked or in bad condition, replace them prior to starting the pump. The pump should be stopped immediately if the temperature is too high. Inspect and if need be, have a technician repair it.
PLEASE READ THE FOLLOWING CAREFULLY THE MANUFACTURER AND/OR DISTRIBUTOR HAS PROVIDED THE PARTS LIST AND ASSEMBLY DIAGRAM IN THIS MANUAL AS A REFERENCE TOOL ONLY. NEITHER THE MANUFACTURER OR DISTRIBUTOR MAKES ANY REPRESENTATION OR WARRANTY OF ANY KIND TO THE BUYER THAT HE OR SHE IS QUALIFIED TO MAKE ANY REPAIRS TO THE PRODUCT, OR THAT HE OR SHE IS QUALIFIED TO REPLACE ANY PARTS OF THE PRODUCT.