Use and Care Manual

OPERATION
1
The installaon must conform with local codes or in the absence of local codes go by the Naonal Fuel
Gas Code ANSI Z223.1/NFPA54 natural gas and propane installaon code CSA 8149.1 or propane storage
and handling code B149.2 A
dented, rusted or damaged propane cylinder may be hazardous and should be checked by your local
cylinder supplier. Never use a propane cylinder with a damaged valve connecon. The propane cylinder
must be constructed and marked in accordance with the specicaons for LPG tanks of the US Department
of Transportaon (DOT) or the standard for cylinders, spheres and tubes for transportaon of dangerous
goods and commission. CAN/CSA-B339.
• The cylinder must have listed overlling prevenon device
• The cylinder must have a connecon device compable with the connecon for the appliance
• The cylinder used must include a collar to protect the cylinder valve
• Never connect an unregulated propane cylinder to the heater
• Do not store a spare LP gas cylinder under or neat this appliance
• Never ll the cylinder beyond 80% full
• Place the dust cap on the cylinder valve outlet whenever the cylinder is not in use
Only install the type of dust cap on the cylinder valve that is provided with the cylinder valve. Other
types of caps or plugs may result in leakage of propane.
LEAK TEST
1. Make 2-3oz of test soluon: One part dish soap and three parts water.
2. Apply several drops of soluon where hose aaches to the regulator.
3. Apply several drops of soluon where the regulator connects to the cylinder.
4. Make sure the heater valves are o.
5. Turn the cylinder valve on.
IF BUBBLES APPEAR AT ANY CONNECTION, THERE IS A LEAK
A minimum supply pressure of .5PSI is required for the purpose of input adjustment of propane gas.
Storage of an appliance indoors is permissible only if the cylinder is disconnected and removed from
the appliance. A cylinder must be stored outdoors in a well venlated area out of reach of children. A
disconnected cylinder must have dust caps ghtly installed and must not be stored in an enclosed area
out of children’s reach.
The minimum permissible gas supply pressure of 11 W.C. is required for hose adjustment. The minimum
hourly of 17,500BTU is required input rang. The pressure regulator and hose assembly supplied with the
appliance must be used.
1. Turn cylinder o.
2. Tighten the hose/regulator connecon and perform another leak test. If bubbles connue to appear,
call customer service.
3. If a leak is detected at the regulator/cylinder valve connecon, disconnect then reconnect and perform
another leak test. If you connue to see bubbles aer several aempts, the cylinder valve is defecve.
Contact customer service for a replacement.
4. If no bubbles appear at any connecon, the connecons are secure.
NOTE: Whenever gas connecons are loosened pr removed, you must perform a leak test.