Use and Care Manual

OPERATION
9
It is a good idea to re the heater outdoors for the rst time. This will allow any oils used in the manufacturing
process to be burned off in a safe place. This initial burn should last at least 10 minutes.
VENTILATION : ALWAYS provide fresh air opening in the heated soace of at least three square feet for each
29KW/hr of heater output.
STARTING THE HEATER:
1. Fill the tank with fuel up to fuel guage points to “F”. MAke sure the cap is secure.
2. Plug the power cord into a local, correct plug. The extension cord should be at least 6 feet long. Extension
cord requirements are as follows:
6-10ft : 18 AWG wire. 11-100ft : 16 AWG wire. 101-200ft : 14 AWG wire.
3. Turn the thermostat control knob to the desired setting. The setting range is from 40 °F to 110 °F. Push
the power switch to the ON position. The power indicator lamp and room temperature display will light up
and the heater will start.
If the heater does not re, the thermostat may be set too low. Turn the control knob to a higher setting until
the heater res. If the heater does not start, push the power switch to OFF, then back to ON. If the heater still
does not re, see the Troubleshooting guide.
NOTE: The electrical components of this heater
are protected by a fuse mounted in the PC
board. If the heater fails to re, chek the fuse rst
and replace if necessary. Also check the power
source to be sure that the proper voltage is being
provided to the heater.
STOPPING THE HEATER:
Simply turn the power switch to the OFF position and unplug the power cord.
STOPPING THE HEATER:
1. Wait 10 seconds after shutting off the heater.
2. Turn the power switch to ON position.
3. Be sure to follow all starting procedure precautions.