CENTRIPRO THREE PHASE, 4", MOTOR DATA
EFFICIENCY, THRUST RATING, FUSE/CIRCUIT BREAKER, KVA CODES

Thrust
Rat-
ing
KVA
Code
Standard Fuse DE-TD Fuse Circuit Breaker
CentriPro # HP Volts F.L. S.F.
Meets
NEC
based
FLA
Max.
Value
based
SFA
Meets
NEC
based
FLA
Max.
Value
based
SFA
Meets
NEC
based
FLA
Max.
Value
based
SFA
M05430 0.5
200
62 68
700 #
R 10 15 6 10 10 10
M07430 0.75 69 74 R 15 15 10 15 10 15
M10430 1 66 70 M 15 20 10 10 10 15
M15430 1.5 72 74 L 20 25 10 15 15 20
M20430 2 74 75
900 #
K 25 30 15 20 20 25
M30430 3 77 77 K 35 40 20 25 30 35
M50430 5 76 76
1500 #
J 60 70 35 40 50 60
M75430 7.5 74 74 J 80 90 50 60 70 80
M05432 0.5
230
61 68
700 #
R 6 10 6 6 6 10
M07432 0.75 66 71 R 6 15 6 10 6 10
M10432 1 69 72 M 10 15 6 10 10 15
M15432 1.5 75 76 K 15 20 10 15 15 20
M20432 2 75 75
900 #
K 15 25 15 15 20 20
M30432 3 77 77 J 25 35 15 20 25 30
M50432 5 76 76
1500 #
J 45 60 30 35 40 45
M75432 7.5 75 75 J 70 80 45 50 60 70
M05434 0.5
460
61 68
700 #
R 3 6 3 3 3 6
M07434 0.75 69 73 R 3 10 6 6 3 6
M10434 1 65 69 M 6 10 3 6 6 10
M15434 1.5 72 73 K 10 10 6 6 6 10
M20434 2 74 75
900 #
L 15 15 6 10 10 10
M30434 3 76 77 J 15 20 10 10 15 15
M50434 5 77 77
1500 #
J 25 30 15 20 15 25
M75434 7.5 76 76 L 40 50 25 30 30 35
M100434 10 79 80 K 45 60 25 35 35 45
M15437 1.5
575
73 74 700 # J 6 10 3 6 6 10
M20437 2 78 78
900 #
M 10 10 6 6 10 10
M30437 3 78 78 J 10 15 10 10 10 15
M50437 5 74 75
1500 #
M 20 25 15 15 20 20
M75437 7.5 77 77 J 25 35 20 20 25 30