Instruction Manual
PAGE 17
Residential Water Systems
CentriPro
CONTROL BOXES FOR 6" CENTRIPRO (HITACHI) SINGLE PHASE MOTORS*
Control Box Use On Capacitor Ratings (MFD) Contactor Overload Enclosure Shipping
Order Number Motor No. HP Volts Start Caps Run Caps Rating Circuit Breaker Dimensions Wt. (lbs.).
CB05MC3R 6M051 5 230 189-227uf / 330V 30 / 440V 30A 30A
12.5" H x
15
CB07MC3R 6M071 7.5 230 243 - 292 / 330V 40 / 440V 50A 50A
11" W x 6.7" D
CB10MC3R 6M101 10 230
(Qty 2)
(2) 25 / 440V 70A 70A
161 - 193 / 330V
17.5" H x
27
CB15MC3R
6M151 15 230
(Qty 2)
(2) 35 / 440V 90A
90A 11" W x 6.7" D
CB15MC3R100 ➀
216 - 260 / 330V
100A
➀ Overload circuit breaker is rated at 100 amps versus 90 amp standard in CB15MC. Use in areas with high ambient temperatures to reduce
nuisance tripping.
* Use these control boxes on only CentriPro (Hitachi) motors. Franklin Electric control boxes will not work and will void the CentriPro warranty.
Do not use these control boxes on Franklin Electric 6" motors as the overloads and capacitors are not the same as used by FE, using these
will void FE's warranty.