Instruction Manual

PAGE 19
Residential Water Systems
CentriPro
THREE-WIRE CONTROL BOX WIRING CHARTS
Quick Disconnect ½ – 1 HP
WIRING DIAGRAM
“K” REPAIR PARTS FOR QUICK DISCONNECT STYLE CONTROL BOXES
Order
Capacitor Start Capacitor
Start Relay Standard Relay (Ohms)
Number
HP Volts Order
Capacitor
Voltage /
Order No. Circuit Breaker #2-#5
Number Mfd Quantity
CB05411 .5 115 9K450 250 - 300 125 / 1
9K457
30 700 – 1800
9K566
CB05412 .5 230 9K448 59 - 71 250 / 1
9K462
15
CB07412 .75 230 9K449 86 - 103 250 / 1
9K567
20 4500 – 7000
CB10412 1 230 9K447 105 - 126 250 / 1 25
First Design - Up to June 2009 - Relay tab on bottom, capacitor held by bracket and screw. See pictures below. 208 V use 9K461 relay.
Current Design - Starting June 2009 - Relay tab on top and capacitors, all held by one screw. See pictures below. The relays are designed
for operation in a specic orientation, therefore there are two different numbers now. 208 V use 9K568 relay.
First Design
Tab Down
Current Design
Tab Up