If this fault is detect-
ed while the pump is
running, the control-
ler will attempt to
restart three times
before displaying
this fault. To clear the
fault, turn off power
to the controller, wait
1 minute, turn on
power to the control-
ler. If fault persists
contact installer.
The controller will try
to restart the motor
three times before
displaying this fault.
To clear the fault,
turn off power to the
controller, wait 1
minute, turn on
power to the control-
ler. If fault persists
contact installer.
AQUAVAR SOLO (formerly known as Balanced Flow) TROUBLESHOOTING
FAULT BLINK CODES (continued)
RED LIGHT CODES
Flashes Controller Status Description
3 Blinks Sensor Fault
(continued)
4 Blinks Over Current This fault can be caused by:
• Installing a 1Ø motor - system requires a 3Ø, 200 or 230 V motor.
• Mechanical binding from debris in pump.
• Electrical failure of the motor.
• Incorrect setting of “MOTOR OVERLOAD SETTING (SFA)” switch.
A false “bound pump” error will be displayed if the switch is set too low.
• Pump wire insulation breaking down. Check insulation with megger.
Verify the error by turning power to controller off for 1 minute and then on.
Pump/Motor must be checked if fault persists.
5 Blinks Short Circuit This fault can be caused by:
• Electrical failure of the motor.
• Electrical failure of wiring between controller and motor.
Verify the error by turning power to controller off for 1 minute and then on.
If error persists, motor and wiring between controller and motor must be
checked. Turn power off for 1 minute. Remove the three motor wires from the
terminal block. Check wiring and motor for shorting phase to phase and
phase to ground. Refer to motor’s manual for information on resistance
readings.
Pressure (PSI)
Sensor Output vs. Applied Pressure
Transducer Output (Volts DC)
100 PSI Sensor
200 PSI Sensor
0
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
0255075 100 125 150 175 200