Instruction Manual

PAGE 8
Residential Water Systems
CentriPro
3-WIRE, SINGLE PHASE 4" MOTORS - ELECTRICAL DATA, 60 HERTZ, 3450 RPM
1ST Generation 2008 - 2012
3-WIRE CENTRIPRO MOTOR DATA
Full Load Service Factor
Locked
Rotor
Amps
Winding
Resistance
Required
Control Box
Type
Order
No.
RJ Ref.
#
HP KW Volts SF Amps Watts Amps Watts
Main
(B-Y)
Start
(R-Y)
3-
Wire
with
Q.D.
Cap.
Start
Box
M05411 50C301 0.5 0.37 115 1.6
Y – 11.0
B – 11.0
R – 0
733
Y – 12.6
B – 12.6
R – 0
1021 49.6
0.9 -
1.6
5.7 -
7.0
CB05411
M05412 50C311 0.5 0.37
230
1.6
Y – 5.5
B – 5.5
R – 0
745
Y – 6.3
B – 6.3
R – 0
1033 22.3
4.2 -
4.9
17.4 -
18.7
CB05412
M07412 75C311 0.75 0.55 1.5
Y – 7.2
B – 7.2
R – 0
1014
Y – 8.3
B – 8.3
R – 0
1381 32.0
2.6 -
3.6
11.8 -
13.0
CB07412
M10412 100C311 1.0 0.75 1.4
Y – 8.4
B – 8.4
R – 0
1267
Y – 9.7
B – 9.7
R – 0
1672 41.2
2.2 -
3.2
11.3 -
12.3
CB10412
3-
Wire
with
CSCR
(CR)
or
Mag-
netic
Con-
tactor
(MC)
Con-
trol
Box
M05412 50C311 0.5 0.37 1.6
Y – 4.1
B – 4.1
R – 2.2
720
Y – 4.9
B – 4.4
R – 2.1
955 22.3
4.2 -
4.9
17.4 -
18.7
CB05412CR
M07412 75C311 0.75 0.55 1.5
Y – 5.1
B – 5.0
R – 3.2
1000
Y – 6.3
B – 5.6
R – 3.1
1300 32.0
2.6 -
3.6
11.8 -
13.0
CB07412CR
M10412 100C311 1.0 0.75 1.4
Y – 6.1
B – 5.7
R – 3.3
1205
Y – 7.2
B – 6.3
R – 3.3
1530 41.2
2.2 -
3.2
11.3 -
12.3
CB10412CR
M15412 150C311 1.5 1.1 1.3
Y – 9.7
B – 9.5
R – 1.4
1693
Y – 11.1
B – 11.0
R – 1.3
2187 47.8
1.6 -
2.3
7.9 -
8.7
CB15412CR or
CB15412MC
M20412 200C311 2.0 1.5 1.25
Y – 9.9
B – 9.1
R – 2.6
2170
Y – 12.2
B – 11.7
R – 2.6
2660 49.4
1.6 -
2.2
10.8 -
12.0
CB20412CR or
CB20412MC
M30412 300C311 3.0 2.2 1.15
Y – 14.3
B – 12.0
R – 5.7
3170
Y – 16.5
B – 13.9
R – 5.6
3620 76.4
1.1 -
1.4
2.0 -
2.5
CB30412CR or
CB30412MC
M50412 500C311 5.0 3.7 1.15
Y – 24.0
B – 19.1
R – 10.2
5300
Y – 27.0
B – 22.0
R – 10.0
6030 101.0
0.62 -
0.76
1.36 -
1.66
CB50412CR or
CB50412MC
GENERATION I - 3-WIRE, SINGLE PHASE MOTOR WIRE SIZING CHART
CentriPro Motor Lead Lengths - 3-Wire Motors,, 4" Motors

Motor Rating 60º C and 75º C Insulation - AWG Copper Wire Size
HP Volts kW FLA SFA 14 12 10 8 6 4 3 2 1 1/0 2/0 3/0 4/0
0.5 115 0.37 11 12.6 87 138 221 349 544 867 1090 1376 1734 2188 2761 3485 4391
0.5
230
0.37 5.5 6.3 348 553 883 1398 2175 3467 4359 5505 6935 8753 11044 13942 17564
0.75 0.55 7.2 8.3 264 420 670 1061 1651 2632 3309 4178 5264 6644 8383 10582 13332
1.0 0.75 8.4 9.7 226 359 573 908 1413 2252 2831 3575 4504 5685 7173 9055 11408
1.5 1.1 9.7 11.1 197 314 501 793 1234 1968 2474 3124 3936 4968 6268 7913 9969
2.0 1.5 9.9 12.2 180 286 456 722 1123 1790 2251 2843 3581 4520 5703 7199 9070
3.0 2.2 14.3 16.5 133 211 337 534 830 1324 1664 2102 2648 3342 4217 5323 6706
5.0 3.7 24 27 206 326 507 809 1017 1284 1618 2042 2577 3253
Tables based on values from NEC, Tables 310.16 and 310.17 and NEC, Chapter 9, Table 8 Conductor Properties.
NOTE: Motors and control boxes are designed to operate on 230V systems. Systems with low line voltage, between 200 – 207 volts require
the next larger cable size than shown in the 230V charts. If using a 3-wire motor with control box on a low voltage application switch
to a 208V start relay. The 208V start relay order numbers are found on control box repair part charts in this manual.
Temperature Conversions: 20º C = 68º F, 30º C = 86º F, 60º C = 140º F, 75º C = 167º F, 90º C = 194º F