Owner's manual
Page 13
4
maximum value is ready to be programmed. The
currently programmed maximum motor speed value is
shown on the 3-DIGIT LCD.
4
Enter the motor speed at the maximum mA input
signal value. Press the FIELD button to select the
digit to program. The digit will blink when selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. The % SPEED icon will stop
blinking and the mA icon will blink indicating the
maximum mA value is ready to be programmed. The
currently programmed maximum value is shown on
the 3-DIGIT LCD.
4
Enter the maximum mA input signal value. Note: this
value must be greater than the minimum mA input
signal value. Press the FIELD button to select the digit
to program. The digit will blink when selected..
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. Programming is complete.
4
To exit the programming mode, press the
RUN/STANDBY button and the MODE button at the
same time. The PROGRAM arrow will disappear.
PROGRAM MODE 2
% speed at the maximum input
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
%SPEED
2
MODE
100
PROGRAM MODE 2
maximum input value
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
2
MODE
20.0
mA
Example 1
6
4
8
10
12
14
16
18
20
0
25
50
75
100
Pump Motor Speed (%)
Milliamp input (mA)
4 mA = 0% OUTPUT
20 mA = 100% OUTPUT
Example 2
6
4
8
10
12
14
16
18
20
0
25
50
75
100
Pump Motor Speed (%)
Milliamp input (mA)
4 mA = 100% OUTPUT
20 mA = 0% OUTPUT
Example 4
6
4
8
10
12
14
16
18
20
0
25
50
75
100
Pump Motor Speed (%)
Milliamp input (mA)
4 mA = 20% OUTPUT
20 mA = 50% OUTPUT
MODE 2 PROGRAMMING EXAMPLES
C-1100V