Owner's manual

Page 15
indicating the maximum value is ready to be pro-
grammed. The currently programmed maximum
motor speed value is shown on the 3-DIGIT LCD.
4
Enter the motor speed at the maximum VDC input
signal value. Press the FIELD button to select the
digit to program. The digit will blink when selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. The % SPEED icon will stop
blinking and the VDC icon will blink indicating the
maximum VDC value is ready to be programmed. The
currently programmed maximum value is shown on
the 3-DIGIT LCD.
4
Enter the maximum VDC input signal value. Note:
this value must be greater than the minimum VDC
input signal value. Press the FIELD button to select
the digit to program. The digit will blink when
selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. Programming is complete.
4
To exit the programming mode, press the
RUN/STANDBY button and the MODE button at the
same time. The PROGRAM arrow will disappear.
PROGRAM MODE 3
% speed at the maximum input
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
% SPEED
3
MODE
100
PROGRAM MODE 3
maximum input value
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
3
MODE
10.0
VDC
C-1100V