Owner's manual
Page 17
PROGRAM MODE 4
minimum input value
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
4
MODE
620
Hz
maximum value is ready to be programmed. The
Currently programmed maximum motor speed value is
shown on the 3-DIGIT LCD.
4
Enter the motor speed at the maximum VDC input
signal value. Press the FIELD button to select the
digit to program. The digit will blink when selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. The % SPEED icon will stop
blinking and the Hz icon will blink indicating the
maximum Hz value is ready to be programmed. The
currently programmed maximum value is shown on
the 3-DIGIT LCD.
4
Enter the maximum Hz input signal value (to the
nearest 10 Hz). Note: this value must be greater than
the minimum Hz input signal value. Press the FIELD
button to select the digit to program. The digit will
blink when selected.
4
Press the DIGIT button to change the selected digit.
4
Repeat until all digits are programmed.
4
Press the mode button. Programming is complete.
4
To exit the programming mode, press the
RUN/STANDBY button and the MODE button at the
same time. The PROGRAM arrow will disappear.
PROGRAM MODE 4
% speed at the maximum input
RUN
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
%SPEED
4
MODE
82.5
MODE 4 PROGRAMMING EXAMPLES
Example 1
0
200
400
600
800
1000
0
25
50
75
100
Pump Motor Speed (%)
Frequency input (Hz)
0Hz=0%OUTPUT
1000 Hz = 100% OUTPUT
Example 2
0
200
400
600
800
1000
0
25
50
75
100
Pump Motor Speed (%)
Frequency input (Hz)
0 Hz = 100% OUTPUT
1000 Hz = 0% OUTPUT
Example 3
0
200
400
600
800
1000
0
25
50
75
100
Pump Motor Speed (%)
Frequency input (Hz)
0 Hz = 10% OUTPUT
270 Hz = 75% OUTPUT
C-1100V