Global Water 800-876-1172 • globalw.com Global Water Instrumentation, Inc.
Global Water 800-876-1172 • globalw.com Congratulations! Thank you for purchasing Global Water Instrumentation, Inc.’s Model AD200-4, the “smartest”, most comprehensive automatic voice/pager security dialer available. Representing an exciting new level of achievement, the AD200-4 combines technologically advanced features, ease of programming and reliable operation in a compact, unobtrusive dialer completely compatible with any security alarm system.
Global Water 800-876-1172 • globalw.com I) AD200-4 Checklist a) b) c) d) One (1) ea. MODEL AD200-4 One (1) ea. PHONE CABLE One (1) ea. INSTRUCTION MANUAL Four (4) ea. 1K RESISTORS II) Inspection a) Your AD200-4 unit was carefully inspected and certified by our Quality Assurance Team before shipping. If any damage has occurred during shipping, please notify Global Water Instrumentation, Inc. and file a claim with the carrier involved.
Global Water 800-876-1172 • globalw.com Please Familiarize Yourself With These Instructions Before Installation/Operation. This guide describes how to program and operate the dialer. We strongly recommend that you read the entire manual before attempting to use the unit. To enhance ease of programming and operation, this guide includes: • • A Programming Sample/Quick Setup review (Page 20) with a corresponding Program Planner. A Blank Program Planner (Page 23).
Global Water 800-876-1172 • globalw.
Global Water 800-876-1172 • globalw.
Global Water 800-876-1172 • globalw.
Global Water 800-876-1172 • globalw.com VI) Programming the Dialer a) Overview Please study this section thoroughly before beginning to program the dialer, referring to the Sample Program Planner on page 20. Then, select from among the options for each feature, listing each choice in pencil on the blank Program Planner on page 23. Once the dialer is correctly programmed, list each choice in ink. One copy of the Planner should be kept by the installer; one copy should remain with the end user.
Global Water 800-876-1172 • globalw.com b) Programming Telephone and/or Pager Numbers First Time Installation to Initialize Dialer Follow Steps 1 & 2. 1. Apply power to the unit. • The LCD will read: NOT PROGRAMMED PRESS KEYPAD #1 2. Press 1. • The LCD will change to read: USP AD200-4 X.X • Then: PROGRAM: NUMBERS • Then: SELECT: 1-8 • 0(DONE) 3. You are now ready to begin programming the dialer. All programming can be input before connecting the dialer to a telephone line.
Global Water 800-876-1172 • globalw.com PROGRAMMED IN. If you pressed “1 ” to program in a numeric page : (a) Press the digits of the pager to be called. The numbers will appear on the LCD, as will the following key designations. (b) Press “P” one or more times in accordance with the number of seconds needed to accommodate the pager. (Remember, each “P” provides a 2-second pause). (c) Press the digits of the numeric pager code.
Global Water 800-876-1172 • globalw.com 6. STEP 4 - Repeat steps 1-3 for each number to be programmed in each location. Select any of eight (8) location numbers in Step 1 (SELECT: 1-8) for each number to be programmed. 7. STEP 5 - When you are done programming all desired telephone and/or pager numbers, press “0” to exit this section.
Global Water 800-876-1172 • globalw.com 3. ATTEMPTS ATTEMPTS refers to the number of times the dialer will call each designated number. Both successful and unsuccessful (busy or no answer) call are considered attempts. (a) The LCD will display: PROGRAM: ATTEMPTS ENTER 1-9 (b) Step 1: Press the digit (1-9) corresponding to the number of times you wish the dialer to call each number. 4. MESSAGE MESSAGE refers to the number of times each message will be delivered to each designated number.
Global Water 800-876-1172 • globalw.com 4. 5. 6. 7. 8. OPTION #4 - ID plus 2 OGMs. Select this option if you wish to record one ID of up to 15 seconds in length, and two OGMs, each of which may be as long as 18 seconds.* OPTION #5 - 3 OGMs. Select this option if you wish to record three OGMs, each of which may be as long as 17 seconds. OPTION #6 - ID plus 3 OGMs. Select this option if you wish to record one ID of up to 15 seconds in length, and three OGMs, each of which may be as long as 12 seconds.
Global Water 800-876-1172 • globalw.com (a) The word RECORD will appear in the upper left corner of the LCD, above the instruction: PRESS R. The option selected will appear in the upper right corner. For instance, if you selected option #2, the LCD will read: RECORD OGM1 PRESS R (b) Speak 6-12 inches away from the microphone. Referring to your script and speaking in a normal voice, press and hold R (the word RECORDING will be displayed), releasing the key after you have completed enunciating your messages.
Global Water 800-876-1172 • globalw.com 2. STEP 2 (a) The LCD will read: SELECT: 1-4 0(DONE) (b) Enter the channel you wish to program (1-4). g) Enable/Disable 1. STEP 3 (a) The LCD will read: CH X: ENABLE 1(YES) 2(NO) (“CH X” being the channel selected) (b) Press “1” to enable the channel. Press “2” to disable the channel. h) Exit/Entry Delays Capable of programming up to a maximum of 3 minutes and 20 seconds each. 1.
Global Water 800-876-1172 • globalw.com (a) Press “1” to select a normally open channel. (b) Press “2” to select a normally closed channel. j) Momentary/Continuous Activation 1. STEP 7 The LCD will read: CH X: MOM/CONT 1(MOM) 2(CONT) (a) Press “1” to select a momentary trigger. (b) Press “2” to select continuous activation. k) Numbers Dialed/Outgoing Messages Following these steps allows you to choose which OGM(s) will be delivered and which numbers will be dialed for each channel.
Global Water 800-876-1172 • globalw.com VII) Testing Your System Test your system before an emergency occurs. Do not neglect to review programmed information and verify all elements of your system thoroughly before relying on the dialer to deliver the necessary information to the desired parties accurately and completely. We strongly recommend testing the system in test mode before connecting to a telephone line. The test mode tests the stored information, not the full functionality of the dialer.
Global Water 800-876-1172 • globalw.com Test your system on a regular basis, at least once a week. VIII) Operating Your System You are now ready to begin operating your system, relying on the AD200-4 to work in conjunction with your alarm system to provide 24-hour security reassurance and peace of mind. When in the operating mode, the system will monitor all the enabled channels, initiating dialing when a valid alarm condition occurs.
Global Water 800-876-1172 • globalw.com Under a momentary activation, a single violation of a channel will cause the dialer to initiate delivering all preselected OGMs to all programmed numbers associated with that channel. Under continuous activation, the dialer will initiate the process, terminating it if/when the activated channel is restored to a non-alarm state. Once an alarm has occurred and all attempts satisfied, the dialer will continue to monitor any remaining enabled channel(s).
Global Water 800-876-1172 • globalw.com IX) Sample Program Planner a) Programming Example for Quick Setup Before programming the dialer, study the example shown on this page. This “quick setup” example programs in one telephone number, two numeric pager numbers, two attempts, two repeats, an ID plus two additional OGMs, and channels 1 and 4. Once you understand the setup, use the blank Program Planner on page 23 to begin programming your dialer.
Global Water 800-876-1172 • globalw.com the third phone number in location 6; press “1” to indicate numeric pager; then press, in sequence, “3456789PP5544#” followed by the “*” sign. 4. STEP 4 Press “0” to exit PROGRAM NUMBERS. 5. STEP 5 At the PROGRAM: T-LINE prompt, press “1” to choose tone; press “2” to indicate no PBX; press “2” to program in two dialing attempts per emergency number called; press “2” to program in two message repeats for each call. 6. STEP 6 Press “1” to PROGRAM OGM(S).
Global Water 800-876-1172 • globalw.com 12. STEP 12 Press “0” to exit PROGRAM: CHANNELS. Press “M” to exit programming mode .
Global Water 800-876-1172 • globalw.com Fill out this Program Planner in pencil initially After thoroughly testing your system, redo your Program Planner in ink. One copy should be kept in a safe place by the end user; one copy should be retained by the installer.
Global Water 800-876-1172 • globalw.com X) Specifications a) Dimensions Power source: 9-18VDC Current (OPERATE mode – standby): 28mA typical. Current (OPERATE mode – dialing): 100mA max. Activation: 1) N.C. Activation: dialer activates when an “open” is detected 2) N.O. Activation: dialer activates when a “close” is detected 3) Voltage Activation: N.C. (applied voltage: Min. +5VDC, Max. +28VDC) N.O. (loss of continuous voltage: Min. 0VDC, Max. 0.25VDC) Max.
Global Water 800-876-1172 • globalw.com Pressure Mats – Sealed and Under Carpet Motion Detectors d) Siren S-120: 2” Mini Siren, 12VDC @ 120 mA typical e) Additional Options Data logger: AD-2001-DL: Retains in memory log of alarm events for later retrieval and review. Wireless: AD200-4/W: Wireless version AD200-4 dialer includes wireless pendant transmitter. 24V Application: AD200-4/F: For this option the dialer is configured to operate at 24VDC to 32VDC max. All other specifications apply.
Global Water 800-876-1172 • globalw.com d) Caution Do not use the dialer if a gas leak is suspected or during lightning. e) Problems If liquid or a foreign object penetrates the unit, disconnect it immediately and contact your installer or other qualified technician. Before calling Global Water, please make sure. 1. You have read this manual and understand how to operate the dialer. 2. Your phone line is working. 3. You check out the entire system, including external hookup wiring and sensors attached.
Global Water 800-876-1172 • globalw.com provide reasonable protection against such interference in a residential installation. i) User Instructions If this equipment does cause interference to radio or television reception, which can be determined by turning the equipment off, then on, the user is encouraged to try to correct the interference by one or more of the following measures: 1. 2. 3. 4. 5. XIII) Reorient or relocate radio or television. Increase the separation between the equipment and receiver.