Owner manual

GPRS iCE
3
, V1.30 User Guide
iQuest (NZ) Ltd - PO Box 15169, Hamilton, New Zealand Tel: +64 7 857 0810 Fax: +64 7 857 0811 Email: iquest@iquest.co.nz 13
6.3.4 AT^ICLK Read / Set CLocK
Description: Provides access to the real time clock in the iCE
3
to either read or set the date and time.
Default: “”
Notes: This parameter must be enclosed in quotes (“) and be formatted as a series of two digit
values in this format “yy/mm/dd,hh:nn:ss”, where n = minutes.
Mode Command Responses
Read AT^ICLK? ^ICLK: “08/06/15,12:34:56”
OK
Write AT^ICLK=”08/06/15,12:34:56” OK OR ERROR
Help AT^ICLK=? ^ICLK: “yy/mm/dd,hh:nn:ss”
OK
6.3.5 AT^IDAS Display All Settings
Description: Displays a listing of all the iCE
3
device parameters and their current values.
Default: N/A
Notes: This command is read only.
Mode Command Responses
Read AT^IDAS? [Alphabetic listing of parameters]
OK
6.3.6 AT^IDFC Data Forwarding Character
Description: Defines the ASCII character, that if received will initiate the forwarding of the data packet.
Default: 13 (Carriage Return)
Notes: Range is 0-255. Setting this parameter to zero will disable the forwarding on character
mode. In this situation, use the forwarding after data timeout function (AT^IDTO command).
Mode Command Responses
Read AT^IDFC? ^IDFC: 13
OK
Write AT^IDFC=13 OK OR ERROR
Help AT^IDFC=? ^IDFC: (0-255)
OK